21
5. CURTIS handle programmer
Operation precautions:
Handle programmer, the main function is to facilitate unit inspection and maintenance. To
avoid accidents, it is not allowed to be used to adjust the controller parameters. After
modifying the parameter, it will be saved automatically, just turn off the key switch and restart
the unit.
CURTIS handle programmer can be connected when the controller is powered on or off.
The unit fault code reading procedure:
1. Connect handle programmer to controller,then turn on the key switch
2. According to the menu list of CURTIS handle programmer, find: Faults.
3. Running the unit, the English Fault Code will appear when cursor is flashing. Refer to the
fault code table for interpretation.
The unit signal detection
1. Connect handle programmer to controller,then turn on the key switch
2.According to the menu list of CURTIS Handle programmer, find: Monitor...
3.If necessary, open the corresponding sub-item of the detection menu. Run the unit and
observe the change of value