Orlan®
ISO 9001
Wood gasication boiler at 18- 80 kW
Operating manual

Other manuals for Eko-Vimar Orlanski Orlan 18

Questions and Answers

  • C
    cannonbruceAug 15, 2025
    Why my Eko-Vimar Orlanski Boiler doesn’t reach the temperature needed?
    • R
      Ryan ThomasAug 15, 2025
      If your Eko-Vimar Orlanski Boiler isn't reaching the desired temperature, several factors could be responsible. You might be experiencing issues when starting the fire. The wood you're using might be too moist, so ensure you're using properly seasoned wood. Other potential causes include choked primary or secondary air conduits, a choked smoke tube in the heat exchanger (clean it with the supplied cleaning shield), incorrect regulation of air and wood gas, or damage to the nozzle, fan's gasket, or the fan itself.
  • P
    Paul CrawfordAug 18, 2025
    What to do if the fan is not working on my Eko-Vimar Orlanski Boiler?
    • R
      Ricky NicholsonAug 19, 2025
      If the fan on your Eko-Vimar Orlanski Boiler isn't working, it could be due to several reasons. The thermal protection might be engaged, indicating the boiler is overheating, so investigate the reasons for boiler overheating. There might be no power in the regulator, so check the fuse and wiring. The fan could be blocked, so inspect and clean the fan.
  • T
    Tracy WilsonAug 21, 2025
    How to fix a regulator that doesn't work on Eko-Vimar Orlanski Orlan 18 Boiler?
    • T
      Travis GarciaAug 22, 2025
      If the regulator on your Eko-Vimar Orlanski Boiler isn't working, there are a few things you can check. First, ensure that the unit is receiving power by checking the wiring and circuit breakers. Also, inspect and repair the live wire if damaged.
  • B
    Brittany GarnerAug 25, 2025
    What causes explosion or “puffing” in the firebox of Eko-Vimar Orlanski Orlan 18 Boiler?
    • S
      shawn74Aug 26, 2025
      If you're experiencing explosions or puffing in the firebox of your Eko-Vimar Orlanski Boiler, consider the following: There may be problems with startup. The chimney draught might be too low (below 10 Pa) or too intensive (over 20 Pa). In the first case rebuild chimney or consider use of WKO exhaust fan, in the second case use exhaust regulator. Also, the wood might be too small or too dry, in this case mix with larger humidity fuel as to increase humidity level (in about 15- 35%). Finally, clogged heat exchanger tubes can cause this issue, clean the exchanger.
  • S
    Sheryl AnthonyAug 28, 2025
    Why is smoke coming out of the Eko-Vimar Orlanski Orlan 18's door?
    • S
      Stacy BrownAug 28, 2025
      If you see smoke coming out of the door of your Eko-Vimar Orlanski Boiler, it could be due to a leak on the seal rope, in this case adjust door hinge per instructions. Another possibility is a worn seal rope, or a damaged door, in such cases replace rope or replace door.
  • R
    Ryan PollardSep 1, 2025
    How to fix a noisy fan on Eko-Vimar Orlanski Orlan 18 Boiler?
    • T
      Tony AlvarezSep 1, 2025
      If the fan on your Eko-Vimar Orlanski Boiler is making noise, check the following: the fan clips may be loosened, check, turn the clips tight. The fan's blades may be unclean, so check and clean them. There might be debris in the fan's cover, so check and clean it.
  • A
    Amanda BergSep 4, 2025
    Why is smoke coming out of the cleaning cover of my Eko-Vimar Orlanski Orlan 18 Boiler?
    • H
      heatherortizSep 4, 2025
      If you notice smoke coming out of the cleaning cover of your Eko-Vimar Orlanski Boiler, it could be due to: a leak on a seal rope, in this case door regulation is needed. The seal rope might be worn, so rope’s replacement is required. The cover may be warped due to overheating, in this case cover’s replacing is needed.
  • H
    Heather VelezSep 7, 2025
    What to do if smoke comes out while loading Eko-Vimar Orlanski Orlan 18 Boiler?
    • N
      nicolasbakerSep 7, 2025
      If smoke is coming out while loading your Eko-Vimar Orlanski Boiler (although a little smoke is acceptable), it might be caused by intensive wind blowing the fumes into the chimney, in this case consider installing a special chimney cap. Another cause may be an inadequate chimney, so consult a chimney maintenance professional (chimney sweep).
  • D
    Dawn GreenSep 12, 2025
    Why is the fan on my Eko-Vimar Orlanski Boiler working poorly?
    • H
      Hannah GomezSep 12, 2025
      If the fan on your Eko-Vimar Orlanski Boiler is working poorly, it might be due to dirty fan blades or pitch on the fan cover. In both cases, check and clean the fan.

Eko-Vimar Orlanski Orlan 18 Specifications

General IconGeneral
BrandEko-Vimar Orlanski
ModelOrlan 18
CategoryBoiler