3. Installation
Wood boilers are to be installed according to the present norms and rules. The requirements of
norm PN 87/B 02411 according building of solid fuel boiler room and the norm PN-91/B-02413 ac-
cording open system boilers’ producing should be taken into account.
Eko-Vimar Orlański company prescribes using chimney inputs which preserve against the
chimney permeating. The company doesn’t take responsibility in case of faults resulting from not
using chimney inputs.
1. Chimney ue should correspond to the parameters of „DIAGRAM OF CHIMNEY CHOSING
ACCORDING TO THE DIN 4705 NORM”.
2. Boiler room should be large enough to enable boiler’s cleaning (>2,2 m).
3. The distance between the boiler and the partitions should enable right access for all of the
boiler’s parts - it shouldn’t be less than - look at “Orlan boiler’s placing”.
Orlan boiler’s placing
4. There shouldn’t be any cables nor electric installations which aren’t for boiler’s room using.
Before smoke outlet’s connecting to the chimneyue, there should be a chimney sweep’s ap-
proval.
According to the PN-EN 303-5 norm accumulation tank should be assembled together with wood
boiler - its capacity is listed in reference to the . 4.2.5. point in the norm