11 PLATINUM FLX™ User Manual
LAMP INSTALLATION
LAMP REPLACEMENT
Please note that due to the nature of the Philips
Platinum
20
R Lamp and the optical path of the fixture, the lamp
MUST BE replaced at 1,500 hours.
Use only Genuine Original Philips Platinum 20R
Lamps.
Other brand lamps may cause damage and void warranty!
INSTALLING OR REPLACING THE LAMP
To ensure a proper/safe lamp change, carefully read all the following instructions.
LAMP PROTECTION CIRCUITRY
Because of the nature of the extreme heat associated with the Philips Platinum 20 R
lamp and the tight nature of the internal optical system, it is IMPERATIVE that the
lamp be replaced every 1,500 Hours. This is done to protect the internal optical
system as well as prevent accidental lamp explosion, which could lead to hot glass
particles falling from the fixture.
FAILURE TO CHANGE THE LAMP WITHIN 300 HOUR of the 1,500 HOUR RATED
LIFE, WILL CAUSE THE FIXTURE TO AUTOMATICALLY SHUT DOWN!
At 1,500 Hours the LCD control display will begin to flash, “Replace The Lamp” and
the lamp will flicker for the first five minutes of operation. At this point the lamp has
reached the maximum rated life and should be replaced immediately. After the
lamp has flickered for about five minutes it should strike normally allowing the fixture
to be used temporarily until a replacement lamp can be installed. The fixture will
continue to operate for an additional 300 hours, however the “Replace the Lamp”
warning will continue to flash in the display. Keep in mind that the flicker protection
circuitry will only work for about 300 Hours (lamp clock life of 1,500-1,800 Hours).
After 1,800 Hours the fixture will no longer respond to DMX commands and
immediately enter a hibernation mode that will electronically discontinue all fixture
functionality with the exception of a few menu commands. The fixture will continue
to enter hibernation mode until the lamp is replaced and the lamp clock has been
reset. To replace the lamp follow the safety guidelines and procedures listed on the
next page.