Fault Finding
No. of Fault Remedy
Flashes
1 No flame detected Check gas supply.
2 Overheat Check there is water in the appliance. We recommend
you wait at least 5 to 10 minutes to allow the heater to
cool before clearing lockout as described below.
3 Low/high supply voltage Ensure voltage is above 10V at the heater and below 15V.
5Other/internal fault Attempt to clear lockout as shown below. If this fails
contact: Heater Support: 0845 217 2933.
To clear any lockout switch off and back on within 2.5 seconds.
TECHNICAL SPECIFICATIONS*
WATER Nominal Tank volume 8 ltrs
Pressure relief valve setting 3 bar
Maximum water inlet pressure 1.9 bar
GAS Gas Type Butane and Propane
CAT I3+ (29/37)
CAT I3B/P (30)
Heat input (net) 1.5 kW
Gas connection 8mm OD copper pipe
ELECTRICITY Supply 12V d.c. +230V a.c. 50Hz
Current consumption, 230V 3.25/6.5 A
Max. current consumption, 12V 0.36A (0.01A on standby)