100
AutoRef Averaging
When <DISPLAY> <REF LVL> is set to AUTO, this parameter controls
the amount of baseline noise averaging.
AutoRef Debounce
When <DISPLAY> <REF LVL> is set to AUTO, this parameter controls
the amount of signal amplitude change required to retrigger
automatic reference determination.
AutoRef Offset
When <DISPLAY> <REF LVL> is set to AUTO, this parameter allows fine-
tuning of the amount of noise displayed above/below the
panadapter's baseline.
CW TX in SSB Mode
If set to YES, CW may be transmitted when the K4 is in LSB or USB
mode. This applies to the built-in keyer, external keying, and the
"KY<TEXT>;" remote control command.
Note that in SSB modes, the M1..M4 message switches are assigned to
voice DVR play, so they cannot be used for CW-in-SSB messages.
However, CW messages can still be sent in this case by creating
macros with the desired text. These macros can then be assigned to
programmable switches.
DIGOUT1 (ACC jack pin 11)
DIGOUT1 is an open-drain output that can be used to control external
equipment. It is stored per-band. On the 160-6 meter bands it is also
stored separately per-antenna if a KAT4 ATU is installed. The default is
OFF (floating), while ON = pull the line to ground (0 V). Max load
current in the ON state is 15 mA; max. load voltage in the OFF state is
25 V DC.