Service Manual
WMZ Series
REFRIGERANT
R407C
R22
COOLING ONLY
HEAT PUMP
DECEMBER 2004
Indoor Units Outdoor Units
WMZ 7 GCZ 7
WMZ 9 GCZ 9
WMZ 12 GCZ 12
WMZ 17 GCZ 14
WMZ 22 GCZ 24
Question and Answer IconNeed help?

Do you have a question about the Electra WMZ Series and is the answer not in the manual?

Electra WMZ Series Specifications

General IconGeneral
BrandElectra
ModelWMZ Series
CategoryAir Conditioner
LanguageEnglish

Summary

Introduction to WMZ Series

General Overview

Details the WMZ split wall mounted range, including cooling only and heat pump models.

Main Features

Highlights key features like R22/R407C compatibility, microprocessor control, and low noise operation.

Indoor Unit Components

Describes the casing, fan, coil, flaps, and control box of the indoor unit.

Filtration System

Outlines the available air filters: pre-filters, electrostatic, and active carbon filters.

Control System Overview

Explains the microprocessor indoor controller and infrared remote control.

Outdoor Unit Description

Details the outdoor unit installation, construction, and components like compressor and fan.

Tubing Connections

Information on flare type interconnecting tubing requirements.

Accessories and Documentation

Covers optional accessories like the All Season Kit and inbox documentation.

Matching Table

Table showing compatible indoor and outdoor units for R407C/R22.

Product Data Sheets

R407C Product Data

Detailed specifications for WMZ-7/GCZ-7 models using R407C refrigerant.

R22 Product Data

Detailed specifications for WMZ-7/GCZ-7 models using R22 refrigerant.

Rating Conditions

Standard Operating Conditions

Defines standard conditions for cooling and heating as per ISO and EN standards.

Operating Limits for R407C

Specifies indoor and outdoor operating limits for R407C units in cooling and heating.

Operating Limits for R22

Specifies indoor and outdoor operating limits for R22 units in cooling and heating.

Outline Dimensions

Indoor Unit Dimensions

Provides dimensional drawings for WMZ 7, 9, 12 and WMZ 17, 22 indoor units.

Outdoor Unit Dimensions

Shows dimensional drawings for GCZ 7, 9, 12, 17, and 22 outdoor units.

Performance Data and Pressure Curves

Cooling and Heating Performance Tables

Detailed cooling and heating performance data for various models (WMZ 7-22).

Capacity Correction Factors Due to Tubing Length

Factors to adjust performance based on refrigerant pipe length for cooling and heating.

Pressure Curves

Graphical data showing suction and discharge pressures versus outdoor temperature.

Sound Level Characteristics

Sound Pressure Level

Illustrates sound pressure measurement methods for different unit types.

Sound Pressure Level Spectrum

Presents NC (Noise Criteria) curves for indoor units WMZ 7 and WMZ 9.

Outdoor Unit Sound Levels

Provides SPL and SPW (dB(A)) values for outdoor units across different models.

Outdoor Unit Sound Pressure Level Spectrum

Shows NC curves for outdoor units in cooling and heating modes.

Electrical Data

Single Phase Unit Electrical Specifications

Details power supply, current, circuit breaker, and wiring for single-phase units.

Wiring Diagrams

Indoor Unit Wiring

Wiring diagrams for WMZ 7, 9, 12 and WMZ 17, 22 indoor units.

Outdoor Unit Wiring

Wiring diagrams for GCZ 7, 9, 12, 17 and GCZ 22 outdoor units.

Electrical Connections

Indoor and Outdoor Unit Connections

Illustrates the electrical connection diagram between indoor and outdoor units.

Refrigeration Diagrams

Heat Pump Model Refrigeration Flow

Shows refrigeration cycle diagrams for heat pump models in cooling and heating modes.

Cooling Only Model Refrigeration Flow

Illustrates the refrigeration cycle for cooling-only models.

Tubing Connections

Tubing Specifications and Torque Values

Details tubing sizes, torque values, and component identification for connections.

Oil Trap Requirements

Guidance on installing oil traps based on unit installation height.

Control System

Electronic Control Introduction and Jumpers

Overview of the electronic control system and its jumper settings for different groups.

Control System Legend and PCB

Explanation of system abbreviations and identification of main PCB components.

General Operating Functions

Details on compressor, fan, heating element, and thermistor operations and protections.

Cooling Modes and Operations

Covers general cooling, cooling with autofan, and auto cooling modes.

Heating Modes and Operations

Explains heating modes, IF operating rules, HE operation, and temperature compensation.

Automatic and Dry Modes

Details automatic cooling/heating, dry mode operations, and system protections.

Timer, Forced, and Sleep Modes

Explains timer functions, forced operation, and sleep mode adjustments and timing.

Self-Test Procedures and Indicators

Covers controller self-tests via jumper or remote, and unit indicators/controls.

Clock Random Delay Function

Details the clock random delay feature and its activation logic.

Troubleshooting

Troubleshooting Symptoms and Solutions

Lists common symptoms, probable causes, and corrective actions for unit malfunctions.

Exploded Views and Spare Parts Lists

Indoor Unit Exploded Views and Parts

Provides exploded views and part lists for WMZ indoor units (7, 9, 12, 17, 22).

Outdoor Unit Exploded Views and Parts

Provides exploded views and part lists for GCZ outdoor units (7, 9, 12, 17, 22).

Optional Accessories

A.S.K (All Season Kit) Installation

Details the installation of the All Season Kit for low-temperature cooling operation.

Appendix A

Installation and Operation Manuals

References to the Installation and Operation Manuals for WMZ 7, 9, 12 and 17, 22.

Related product manuals