Overview of the Trio/Quattro DCI Multi series as a high-level technology product.
Details the high technology and system features of the multi-split inverter system.
Information regarding the flare type interconnecting tubing to be produced on site.
Details on installation and operation manuals supplied with each indoor unit.
Table showing outdoor and indoor unit compatibility.
Details on various indoor unit configurations for Trio and Quattro systems.
Technical specifications for the Trio DCI outdoor unit.
Technical specifications for the Quattro DCI outdoor unit.
Technical data for the WNG 9 DCI indoor unit.
Technical data for the WNG 12 DCI indoor unit.
Technical data for the WNG 18 DCI indoor unit.
Technical data for the ECF 9 DCI indoor unit.
Technical data for the ECF 12 DCI indoor unit.
Technical data for the ECF 18 DCI indoor unit.
Technical data for the PXD 9 DCI indoor unit.
Technical data for the PXD 12 DCI indoor unit.
Technical data for the PXD 18 DCI indoor unit.
Technical data for the LS 35 DCI indoor unit.
Defines standard operating conditions for cooling and heating.
Specifies temperature and voltage limits for cooling and heating.
Dimensional drawings for WNG 9/12 DCI wall-mounted indoor units.
Dimensional drawings for WNG 18 DCI wall-mounted indoor unit.
Dimensional drawings for ECF 9, 12, 18 DCI cassette indoor units.
Dimensional drawings for PXD 9, 12, 18 DCI floor/ceiling indoor units.
Dimensional drawings for the LS 35 DCI ducted indoor unit.
Dimensional drawings for TRIO and QUATTRO DCI outdoor units.
Cooling and heating performance for Trio and Quattro DCI combinations.
Cooling capacity factors and correction factors for various indoor units.
Cooling and heating correction factors based on tubing length.
Model-specific corrections and a calculation example for performance data.
Pressure curves for TRIO DCI (cooling/heating, technician mode).
Pressure correction factor based on tubing length.
Correction factor (Fc) based on outdoor unit code.
Pressure curves for QUATTRO DCI (cooling/heating, technician mode).
Example calculation for pressure curves.
Details on power supply, wiring, and cable specifications.
Wiring diagram for Trio and Quattro DCI outdoor units.
Diagram illustrating the refrigerant system of the outdoor unit.
Guidelines for tube bending and torque specifications for flare nuts and caps.
Lists abbreviations and provides a system overview with block diagram.
Covers initialization, capacity codes, matching, and faults.
Manages indoor unit communication, thermistor failures, and temperature sensors.
Details fan control, auto modes, dry mode, heating elements, and special functions.
Controls outdoor fan speed and manages thermodynamic protections.
Covers deicing procedures and condensate overflow protection.
Installation/technician test modes and user interface operation.
Jumper settings, system parameters, and compressor/fan configurations.
Common system issues, probable causes, and corrective actions.
Issues related to compressor operation, mode selection, and refrigerant.
Detailed fault descriptions and corrective actions for outdoor and indoor units.
Procedures for checking key parts like voltage, fuses, fan, and compressor.
Troubleshooting electromagnetic interference and high voltage safety.