INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the Gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT INSTALL YOUR DRYER IN A CLOSET WITH A SOLID DOOR.
4. A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and
bottom of the door, is required. Air openings are required to be unobstructed when a door is
installed. A louvered door with equivalent air openings for the full length of the door is acceptable.
MINIMUM INSTALLATION CLEARANCES (Inches)
SIDES REAR TOP FRONT
Alcove 0 (0 cm) 0 (0 cm) 15 (38.1 cm)
Closet 0 (0 cm) 0 (0 cm) 15 (38.1 cm) 1 (2.54 cm)
Closet door ventilation required: 2 louvered openings each
60 square inches (387 square centimeters) 3 inches
(7.6 cm) from bottom and top of door.
NOTE: Under counter and stack models - 0 inches (0 cm) for sides, rear, and top.
THIS DRYER MUST BE EXHAUSTED OUTDOORS