Problem and alarm code Possible cause and solution
The programme does not start. Make sure that the appliance door is closed.
If the delay start is set, cancel the setting or
wait for the end of the countdown.
The appliance recharges the resin inside
the water softener. The duration of the pro‐
cedure is approximately 5 minutes.
The appliance does not fill with wa‐
ter.
The indicator flashes 1 time
intermittently.
Acoustic signal sounds 1 time in‐
termittently.
Make sure that the water tap is open.
Make sure that the pressure of the water
supply is not too low. For this information,
contact your local water authority.
Make sure that the water tap is not clogged.
Make sure that the filter in the inlet hose is
not clogged.
Make sure that the inlet hose has no kinks
or bends.
The appliance does not drain the
water.
The indicator flashes 2 times
intermittently.
Acoustic signal sounds 2 times
intermittently.
Make sure that the sink spigot is not clog‐
ged.
Make sure that the interior filter system is
not clogged.
Make sure that the drain hose has no kinks
or bends.
The anti-flood device is on.
The indicator flashes 3 times
intermittently.
Acoustic signal sounds 3 times
intermittently.
Close the water tap.
Make sure that the appliance is correctly in‐
stalled.
Make sure the baskets are loaded as in‐
structed in the user manual.
Malfunction of the water level detec‐
tion sensor.
The indicator flashes 4 times
intermittently.
Acoustic signal sounds 4 times
intermittently.
Make sure that the filters are clean.
Switch the appliance off and on.
Malfunction of the wash pump or
the drain pump.
The indicator flashes 5 times
intermittently.
Acoustic signal sounds 5 times
intermittently.
Switch the appliance off and on.
The temperature of the water inside
the appliance is too high or malfunc‐
tion of the temperature sensor oc‐
curred.
The indicator flashes 6 times
intermittently.
Acoustic signal sounds 6 times
intermittently.
Make sure that the temperature of the inlet
water does not exceed 60°C.
Switch the appliance off and on.