Calibration of the level control system
CLS 1.jpeg
CLS 2.jpeg
1
2
Wascator FOM 71 CLS
Calibration of the level control
system
During testing compliant with the IEC 604456
Ed5 standard, this calibration does not control
the supply water values of the wash program.
However, where wash programs use the scale
for controlling the water intake level, the control
becomes active and manages other levels inside
the machine such as empty machine, heating
element safety level and overfill. These levels
are needed for the safety values of the machine.
Therefore, the level must be adjusted and main-
tained in accordance with the procedure descri-
bed below.
Assembling the ruler
Fig. 1-2: Mount the scale and ruler as shown in
the pictures.