Electrolux KSV35HRC Specifications

General IconGeneral
TypeSplit System
Cooling Capacity3.5 kW
Energy Efficiency Ratio (Cooling)3.21
Coefficient of Performance (Heating)3.61
Power Supply220-240V, 50Hz
Power Consumption (Cooling)1090 W
Noise Level (Outdoor Unit)52 dB(A)
RefrigerantR410A
Indoor Unit Weight9 kg
Air Flow (Indoor Unit)600 m³/h

Summary

Safety Precautions

General Warnings

Critical safety warnings to prevent electrical shock, injury, or fire.

Cautions

Important cautions regarding tool usage, installation, and environmental factors.

Electrostatic Discharge (ESD)

ESD Safety Procedures

Procedures for safe handling of ESD sensitive items.

Installation Brief

Installation Site Instructions

Indoor Unit Site Selection

Guidelines for selecting the optimal installation location for the indoor unit.

Outdoor Unit Site Selection

Guidelines for selecting the optimal installation location for the outdoor unit.

Piping, Flare Work & Torque Settings

Electrical Work

Wiring Installation

Steps for connecting indoor and outdoor unit electrical wiring.

Safe Electrical Working Practices

Capacitor Discharge

Troubleshooting - Fault Codes

Fault Code Descriptions

Explains fault codes and their corresponding LED indications.

Loading EEPROM Malfunction (EE)

Fault code for EEPROM loading malfunction.

Communication Fault (E6)

Fault code indicating a communication error.

IPM Protection (H5)

Fault code related to IPM protection issues.

Refrigeration System Blockage/Leak (E3)

Fault code for refrigeration system blockage or gas leakage.

Troubleshooting - Condition Codes

DRED Conditions (D1, D2, D3)

Condition codes related to Demand Response Electrical Device operation.

Anti-Freeze Protection Conditions (E2, FH)

Condition codes for anti-freeze protection and frequency drop.

Troubleshooting - Other Faults

Indoor Fan Stall (H6)

Fault code for indoor fan stall condition.

Outdoor DC Fan Motor Malfunction (L3)

Fault code for outdoor DC fan motor malfunction.

Compressor Overload Protection (H3)

Fault code for compressor overload protection.

Indoor Unit Disassembly

Outdoor Unit Disassembly

Sizing Guide