To manually activate a defrost cycle it is necessary to keep the tem-
perature decrease button pressed for at least 3 seconds.
The display shows the message dFb/defrost
start for a few seconds
and the icon signalling activation of the defrost cycle lights up.
Defrost can be manually stopped by pressing the DEF/decrease tem-
perature button again for at least 3 seconds. The display shows the
message dFE/defrost
end.
Defrost in the range models is carried out following the algorithm va-
lues: 1) parameter dF0, associating the actual hours of compressor
operation, 2) parameter dF1, number of door openings, where para-
meter dF0 must be reduced ,3)parameter dF2, minutes to be add to
parameter dF1 from subtracted to parameter dF0,to anticipate defrost .
Parameter dl remains active if these values are not respected.
In case of activation of continuous cycle, by pressing the temperature
decrease button for more than 5 seconds the display will show the
message ccb, at the same time as the temperature the message tc
will appear, meaning that “turbo cooling” has been activated. The cycle
will end for time, by parameter CC, or for temperature by parameter
AL, or by pressing the button again.
The humidity value is activated by pressing the corresponding button.
Three modes can be activated: low, medium, high % .F0= 3
The function activates the evaporator fans following the logic of low,
medium and high humidity % to be obtained in the compartment.
The parameters functioning in this are: