EasyManuals Logo

Electrolux R Series User Manual

Electrolux R Series
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
0209 7
5
01106073
PageNotice Date
OPERATING
HANDBOOK
"Gas ignition fault" message
(only on gas-heated machines).
The screen will alternately display this ashing
message and the service screen. This means that the
lighting of the gas burners has been requested.
If this message has been displayed over 30 seconds,
the gas burner is not ignited.
The heating system falls
into safety state and heating is cut off. Try again and
follow the starting procedure.
Press any key to display the following menu.
After an additional failure, please check the gas
heating running. If the fault remains, consult your
after-sales service.
Gas burner ignition fault (only for machines using gas heating)
Message: "Reset igniter"
The message on the screen will then ask you if you
wish to reset the igniter.
Press on one of the two buttons on the left to restart
the gas igniter
.
Press the "STOP" button to stop the machine.
Reset the igniter (only for machines using gas heating)
Error
Gas Ignition
Dx °C 2.5m/min 000
Reset Ignitor STOP
Problem
Fault with the heating system
Message: "Problem - fault with the heating
system".
The screen appears if, after a certain time
(approximately 20 minutes) the cylinder temperature
remains below 100°C.
Try to restart the machine.
If the problem continues, please consult your after-
sales service department.
Fault with the heating system