EasyManua.ls Logo

Electrolux W4400H - Programme Unit

Electrolux W4400H
186 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
73
Programme unit
• I/O cards A11 and A12
The I/O cards are controlled by the CPU card via a serial interface. The
I/O cards feature outputs, which, via the communication cards in the
rear electric box, control various machine functions, such as the wa-
ter valves, heater connection and drain valve. On the input connection
blocks, it is possible to connect signals for control of e.g. the detergent
supply.
The cards also have inputs for emergency stop and door lock ACK.
6060
M1
Temp.
1
Door lock controller
A31
Motor
controller
U1
Level
guard B2
Door lock
A41
Programme unit
A1
Transformer
T10
Water
valves
Drain
valves
Level guard
Emergency
stop
I/O card 1
A11
I/O card 2
A12
Display card
Card reader
Control panel
I/O card 3
A13
A52
Tilting function

Table of Contents