79
Programme unit
Outputs on I/O cards
I/O-card I/O-card 1 A11
Connection block No. Switch No. Function
Outputs
X4: 1 Neutral
2 1 Door lock relay, phase (normally open)
3 Neutral
4 1 Door lock relay, phase (normally open)
X7: 1 2 Drain 1 (Y1), phase (normally open)
2 Common neutral
3 2 Drain 1 (D1), phase (normally closed)
X8: 1 3 Heater relay (K21)
2 Neutral
X9: 1 9 Hot water inlet (Y25)
2 8 Powder 5 (Y22)
3 10 Powder 4 (Y14/24)
4 7 Cold water inlet (Y15)
5 6 Powder 3 (Y13)
6 5 Powder 2 (Y12)
7 4 Powder 1 (Y11)
8 N (common neutral)
X14:1 14 Signal 4, external detergent pump
2 12 Signal 3, external detergent pump
3 13 Signal 2, external detergent pump
4 11 Signal 1, external detergent pump
5 N (common neutral)
I/O-card 3 A13
Function
Outputs
X9: 1 Phase K42 NC to Y41A
2 Phase K41 NC to Y42A
3 Phase K41B and Y42B
4 Phase X972:3 to K43
5 Phase control unit for tilting
8 N (common)