6.24. Alarm Functions
6.24.1. Low Battery Alarm
Send SMS “lowbattery+password+space+on”, it will send SMS “low battery+latitude/longitude”
to authorized numbers 2 times in total at 15 minutes interval when voltage of battery is going to
be about 3.55V.
This function is activated by default, send SMS “lowbattery+password+space+off” to deactivate.
6.24.2. External Power off alarm
Send “extpower+password+space+on” to activate, it will send SMS “power
alarm+latitude/longtitude” to authorized numbers every 3 minutes when external power is cut off.
This function activates as default.
Cancel: Send SMS “extpower+password+space+off” to deactivate it.
6.24.3. GPS blind Spot alert
This function deactivates by default, To activate it pls send SMS
“gpssignal+password+space+on”, it will send alert SMS “no gps+last valid latitude/longitude” to
authorized number before lost signal
Send SMS “gpssignal+password+space+off” to deactivate.
6.24.4. SOS
Long Press the SOS button for 3 seconds, the tracker device will send SMS “help me!+lat./long.”
to all the authorized numbers at interval of 3 minutes. It will stop sending such a SMS when any
authorized number reply SMS “help me!” to the tracker.
6.24.5. Geo-fence
Set up a geo-fence for the tracker device to restrict its movements within a district. The unit will
send SMS to the authorized numbers when it goes out of this district.
Set up: When the unit stays immobile in a place for 3-10 minutes, the user can send
SMS“stockade+password+space+latitude,longitude;latitude,longitude” to unit to set the restricted
district. In case of breach, it will send SMS “stockade!+ latitude & longitude” to the authorized
numbers at interval of 3 minutes.

Table of Contents