35
Product description
EN
3.2 Technical data
All information in this section assumes an ambient temperature of 20°C.
3.2.1 Summary of the technical parameters
Technical data Patio
Rated voltage 24 V DC
Force, dynamic (N) 1.500
Force, static (N) 1.200
Stroke speed (mm/s) approx. 6
Stroke length (mm) 150
Rated current (A) approx. 2.3
1)
Output (W) 55
Duty cycle S3 15%
Type of protection IP 65
Temperature range -10°C - +60°C
2)
Limit switches Limit stop deactivation
Connecting rod Secured against rotation
Airborne noise emission > 60 dB (A)
3)
Weight up to 1.5 kg
Tab. 1 Technical parameters
1)
Option without deactivation: If there is a blockage, the control unit must switch off the current
supply within 10 seconds in order to avoid overloading the drive. Observe changeover time of
at least 2 seconds.
2)
Discrepancies in technical data possible.
3)
Noise level 60 dB(A) (with nominal power and without load in accordance with EN ISO 3745)