8
About this document
This User Manual presents a description of a static electricity meter GAMA 100 (G1B.xxx)
and its instruction. Please read this instruction prior to the use of the meter. The
manufacturer does not give any guaranty in case meter is damaged during the exploitation
that contravenes with the instructions and requirements of safety stated in the manual and
meter passport.
The manufacturer is not responsible for the loss in case the meter is parameterized without
accordance with the instructions and recommendations presented in the software description
as well as with tariff order defined by the State. It does not carry the responsibility for the
unprofessional acts of responsible persons in case of full or partial loss of billing data.
User manual presents the description of all possible characteristics, functions and auxiliary
outputs of electricity meter. A concrete meter may not comply with all characteristics
introduced in this manual; however, meter passport defines a precise meter configuration,
possibilities and auxiliary outputs as well as a concrete connection scheme.
The manufacturer has a right to change the information presented in this manual without the
warning. In addition, any copying, transmission and publication of full or partial meter
documentation is forbidden without a written permission of “ELGAMA-ELEKTRONIKA” Ltd.
1 Safety
1.1 Safety requirements
1. Installing, uninstalling, parameterization and verification can be performed only by
authorized organizations that have qualified technicians. Only qualified persons should
install meters.
2. Meter’s connection or disconnection from network should be done when voltage in the
network is turned off. A protection from accidental network voltage connection must be
established.
3. No accessories can be hung on a meter, it is forbidden to hit or strike meter’s case.
4. Precautions must be taken in battery changing procedure: 1) meter has to be
disconnected from electricity network, a protection from accidental network voltage
connection must be assured; 2) use pincers or similar instruments to change battery
(connection/disconnection of a plug).
1.2 Transportation and storage rules
1. Prior to the usage meter must be kept in a closed room in a transportation packing,
where the temperature ranges from 5°C to 40°C and average area humidity is up to
80% when temperature being 25°C. The room must be without harmful gas or steam.
Meter must be kept and exploited in premises protected from dust, aggressive vapors
and gas.
2. Unpacked meters can be kept only in repair workshop. The temperature must range
from 10°C to 35°C, average area humidity must not exceed 80% when temperature
being 25°C.
3. During wintertime meters must be kept in a heated room for 6 hours or more, before
they are used.
4. Meters are to be transported only in closed vehicles (carriage, container, hold). Shake
acceleration is to be up to 30m/s², 80-120 strikes per minute. The temperature must
range from -40°C to +70°C, average area humidity must not exceed 98% when
temperature being 35°C.