- 1 -
Instruction Manual for Multi-function
Panel Meter
Model Elite DCM-12030C
(English version)
Main Features of the Meter
Both forward (Positive) and reverse (Negative)
current flows can be measured.
The CHARGING LED on the right lights when
the battery is charging.
Other LEDs (V, TIME, W, A, AH, %) show what
the display to the left is measuring.
The measured values are shown on two-line
seven-segment multi-function displays:
On the top line is a four-digit display, toggled by
the V/W button between
- Voltage (V), Power (W) and Working Hours (H)
On the bottom line is a three-digit display,
toggled by the A/AH button between
- Current (A), Ampere-hours (AH) and
Remaining Capacity Percentage (%).
There is a flexible calibration process for voltage,
current and Amp-hours/ % capacity
The meter does not require external power when
measuring between 10V and 90V.
The meter consumes very little power for its own
operation.
Specification
Power supply required: DC 10 to 90V (external
or internal)
Measuring range:
(1) Using an external power supply - Voltage 0
to 120.0V / Amp 0 to 30.0A
(2) Using an internal power supply - Voltage 10
to 90.0V / Amp 0 to 30.0A (Figures 1)
Accuracy: Volts ± 1% + 2byte, Amps ± 2% +
5byte
Resolution 0.01V, 0.01A, 0.01W, 0.01Ah
Dimensions: 79mm x 43mm x 30mm
Panel cutout: 76.5mm x 39.2mm
Sampling rate: 5 reading per second
Displays: 4 and 3 digits Red LED
Operating Temperature: 0 to 50°C
Operating Humidity: 35 to 85% Relative
Humidity
Weight: 70g
Question and Answer IconNeed help?

Do you have a question about the Elite DCM-12030C and is the answer not in the manual?

Elite DCM-12030C Specifications

General IconGeneral
Continuity TestYes
Diode TestYes
Power Supply9V battery
DC Voltage Range0-600V
AC Voltage Range0-600V
Resistance Range0-20MΩ
DisplayLCD
Measurement RangeDC Voltage: 0-600V, AC Voltage: 0-600V, AC Current: 0-400A, Resistance: 0-20MΩ

Summary

Main Features of the Meter

Multi-line Display Functionality

Describes the two-line seven-segment display, toggled by V/W and A/AH buttons for voltage, power, hours, current, amp-hours, and percentage.

Power and Calibration Features

Highlights the meter's ability to measure forward/reverse current, indicate charging status, and its flexible calibration process without external power for 10-90V.

Specifications

Power Supply and Measuring Ranges

Details power supply requirements (DC 10-90V) and measuring ranges for voltage and current using external or internal power sources.

Accuracy, Resolution, and Physical Specs

Lists accuracy for volts and amps, resolution, dimensions, panel cutout size, sampling rate, display type, operating temperature, humidity, and weight.

Installation and Setup

Panel Meter Installation Steps

Provides step-by-step instructions for cutting the panel, mounting the meter, connecting it in series, and selecting the power configuration.

Normal Operation and Display Control

Explains default display behavior and how to toggle between different measurements (V, W, H, A, AH, %) using the V/W and A/AH buttons.

Debug Mode and Basic Control

Describes how to enter and exit debug mode using the SET button for calibration and setting adjustments.

Calibration and Settings

Zero and High Voltage Calibration

Guides through calibrating zero and high voltage readings by adjusting the display using V/W and A/AH buttons in debug mode.

Zero and High Current Calibration

Details the process for calibrating zero and high current readings, comparing meter display to a calibrated ammeter.

Setting Rated Battery Capacity

Explains how to set the rated battery capacity (Ah) for accurate remaining capacity percentage display.

Saving and Resetting Configurations

Covers saving settings made in debug mode and resetting the meter to factory default values.

Advanced Settings and Usage

Setting Remaining Amp-hour and Capacity %

Describes how to set the meter to display actual remaining amp-hours and capacity percentage accurately.

Saving Displayed Amp-hour and Capacity Readings

Explains how to save the currently displayed amp-hour and capacity readings by pressing the SET button.