- 1 -
Instruction Manual for Multi-function
Panel Meter
Model – Elite DCM-12030C
(English version)
Main Features of the Meter
• Both forward (Positive) and reverse (Negative)
current flows can be measured.
• The “CHARGING” LED on the right lights when
the battery is charging.
• Other LEDs (V, TIME, W, A, AH, %) show what
the display to the left is measuring.
• The measured values are shown on two-line
seven-segment multi-function displays:
On the top line is a four-digit display, toggled by
the V/W button between
- Voltage (V), Power (W) and Working Hours (H)
On the bottom line is a three-digit display,
toggled by the A/AH button between
- Current (A), Ampere-hours (AH) and
Remaining Capacity Percentage (%).
• There is a flexible calibration process for voltage,
current and Amp-hours/ % capacity
• The meter does not require external power when
measuring between 10V and 90V.
• The meter consumes very little power for its own
operation.
Specification
• Power supply required: DC 10 to 90V (external
or internal)
• Measuring range:
(1) Using an external power supply - Voltage 0
to 120.0V / Amp 0 to 30.0A
(2) Using an internal power supply - Voltage 10
to 90.0V / Amp 0 to 30.0A (Figures 1)
• Accuracy: Volts ± 1% + 2byte, Amps ± 2% +
5byte
• Resolution 0.01V, 0.01A, 0.01W, 0.01Ah
• Dimensions: 79mm x 43mm x 30mm
• Panel cutout: 76.5mm x 39.2mm
• Sampling rate: 5 reading per second
• Displays: 4 and 3 digits Red LED
• Operating Temperature: 0 to 50°C
• Operating Humidity: 35 to 85% Relative
Humidity
• Weight: 70g