9. Technical Parameters
Working voltage: 100~240VAC, 50/60Hz
Temperature measurement range: -5~70°C / 23~158°F
Temperature control range: -5~70°C / 23~158°F
Temperature measurement accuracy: ±0.5°C /±1°F
Temperature resolution: 0.1°C /0.1°F
Humidity measurement range: 5~99%RH
Humidity control range: 5~99%RH
Humidity measurement accuracy: ±5%RH
Humidity resolution: 0.1%RH
Relay contact output capacity: 10A (resistive) / 100 ~ 240VAC
Output power: 2200W (resistive) in total/
200W (inductive) per channel @220VAC,
1100W (resistive) in total/
100W (inductive) per channel @110VAC
Total power consumption: <5W
Working environment temperature: 0°C~60°C / 32~140°F
Storage temperature: -10°C~70°C / 14~140°F
Length of power probe: 1.5m
Length of output power probe: 0.3m
Enclosure size: 165 x 60 x 32 mm
Length of sensor cable: 2m (including probe length)
Best viewing angle of LCD screen: 6 O'clock direction
Wi-Fi type*: 2.4G (not support 5G)
*Only for STC-1000WiFi TH
-16-

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elitech STC-1000WiFi TH and is the answer not in the manual?

Elitech STC-1000WiFi TH Specifications

General IconGeneral
WiFi ConnectivityYes
DisplayLCD
Temperature Measuring Accuracy±0.5 °C
Resolution0.1 °C
Relay Output Capacity10A/250VAC
Humidity Measuring Accuracy±3 %RH
Humidity Resolution1 %RH
App ControlYes
Weight200 g
CertificationCE, RoHS
Temperature Range-50°C to 99°C
Humidity Range0 to 100 %RH
Output TypeRelay
Sensor TypeNTC
Operating Environment-20°C to 60°C, 20% to 85% RH