Describes the function of UP, DOWN, FNC, and SET keys for instrument control and menu navigation.
Explains how to access and navigate the instrument's main menus and their contents.
Accessing and modifying the setpoint value within the Machine Status menu.
Viewing values from connected temperature probes in the Machine Status menu.
Enabling and managing password protection for access to level 1 parameters.
Transferring parameters to and from a Copy Card accessory for quick programming.
Disabling keyboard input via the 'Loc' parameter for security or accidental prevention.
Information on error codes, specifically E1 for probe faults, and status signals.
Description of LED indicators, their states, and associated functions like relay status.
Specifies permitted and unpermitted use, safety precautions, and environmental conditions.
Details on protection, casing, dimensions, temperature, humidity, inputs, outputs, and power.
Configuration parameters for the regulator, including differential, setpoint limits, and mode.
Parameters for regulator protection in case of faulty probes, including delay times.
Parameters for controlling display behavior, such as keyboard locking and temperature units.
Parameters for probe type selection and device version information.
Parameters related to uploading, downloading, and formatting data on the Copy Card.
Illustrates regulator output behavior based on 'Ont' and 'Oft' parameters during error conditions.
Provides connection details for 12V and 230V models, including power supply and sensor inputs.
Describes the function of UP, DOWN, FNC, and SET keys for instrument control and menu navigation.
Explains how to access and navigate the instrument's main menus and their contents.
Accessing and modifying the setpoint value within the Machine Status menu.
Viewing values from connected temperature probes in the Machine Status menu.
Enabling and managing password protection for access to level 1 parameters.
Transferring parameters to and from a Copy Card accessory for quick programming.
Disabling keyboard input via the 'Loc' parameter for security or accidental prevention.
Information on error codes, specifically E1 for probe faults, and status signals.
Description of LED indicators, their states, and associated functions like relay status.
Specifies permitted and unpermitted use, safety precautions, and environmental conditions.
Details on protection, casing, dimensions, temperature, humidity, inputs, outputs, and power.
Configuration parameters for the regulator, including differential, setpoint limits, and mode.
Parameters for regulator protection in case of faulty probes, including delay times.
Parameters for controlling display behavior, such as keyboard locking and temperature units.
Parameters for probe type selection and device version information.
Parameters related to uploading, downloading, and formatting data on the Copy Card.
Illustrates regulator output behavior based on 'Ont' and 'Oft' parameters during error conditions.
Provides connection details for 12V and 230V models, including power supply and sensor inputs.
| Type | Electronic thermostat |
|---|---|
| Temperature Range | NTC: -50 to 110°C, PTC: -55 to 150°C |
| Display | LCD |
| Power Supply | 12 VAC/DC, 24 VAC/DC, 115 VAC, 230 VAC (depending on model) |
| Dimensions | 33.5 x 74 x 59 mm |
| Relay outputs | 1 |
| Serial output | RS485 |
| Resolution | 0.1 °C |
| Accuracy | ±0.5 °C |
| Frontal protection | IP65 |
| Storage temperature | -20 to +70 °C |
| Probe inputs | 1 |
| Digital inputs | 1 |
| Storage temperature range | -20 to +70 °C |
| Protection degree | IP65 |
| Standards | EN 60730-1 |
| Output relay | 8A(3) 250Vac or 20A(8) 250Vac (depending on model) |