HANGER BRACKET INSTALLATION
1) Remove hanger bracket fastened to back of cooler by removing one (1) screw
2) Mount the hanger bracket as shown in Figures 1,2,3, or 4 (Pages. 2-5)
NOTE: Hanger Bracket MUST be supported securely. Add xture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six
(6) 1/4 in. dia. mounting holes.
IMPORTANT: 5-7/8 in. (150mm) dimension from wall to centerline of trap must be maintained for proper t.
INSTALLATION OF COOLER
3) Hang the cooler on the hanger bracket. Be certain hanger bracket is engaged properly in the slots on the cooler back as shown in Figures 1,2,3, or 4 (Pages. 2-5)
4) Remove the four (4) screws holding the lower front panel at the bottom of the cooler (See Fig 7, Pg.5). Remove the front panel by pulling straight down and set aside.
5) Secure cooler frame to wall by installing (2) screws and washers (not supplied). (See Fig. 2, Pg. 4). Make sure the screws engage in a structural member.
6) Connect the supply water to the lter inlet tube.
7) Install trap. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line ts into the trap. Assemble the slip nut
and gasket to the trap and tighten securely.
IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.
BOTTLE FILLER INSTALLATION
8) Remove two (2) mounting screws with 5/32" Allen wrench holding bottle ller to wall mounting plate (See Fig.8, Pg. 4). Note do not discard mounting screws, they will be
needed to secure bottle ller to wall mounting plate.
9) Remove wall mounting plate from Bottle Filler (see Fig 8, Pg. 4). Place wall mounting plate against wall on top of basin. Center the wall mounting plate side to side with the basin. Mark the
six (6) mounting holes with a pencil. Place tape over wiring harnes conection on top of cooler to prevent debris from falling into Connection.
10) Remove wall mounting plate from wall. NOTE: Mounting plate MUST be supported securely. Add xture support carrier if wall will not provide adequate support.
11) Install wall mounting plate to wall using six (6) 7/16" obround mounting holes (mounting bolts not included) (See Fig.4, Pg. 4). Use appropriate fasteners for your wall type.
12) Install gasket on bottom of bottle ller tower with gasket support bracket & (2) screws.
13) Connect water line from cooler to 3/8" john guest tting. Connect wiring harness to the top of cooler. (See Fig. 5, Pg. 4).
14) Place bottle ller on four (4) hooks on the mounting plate installed on wall. Make sure round boss in gasket ts in hole of basin. (See Fig. 8, Pg. 5).
15) Remove lter from carton, remove protective cap, attach lter to lter head by rmly inserting into head and rotating lter clockwise. Ensure that blue label can be read when
lter is installed. (Fig. 12, Pg. 7.)
16) Turn water supply on and inspect for leaks. In both cooler and bottle ller. Fix all leaks before continuing.
17) Once cooler and bottle lter has been inspected for leaks and any leaks found corrected, plug cooler into wall.
18) Reinstall two mounting screws from rst step (See Fig. 8, Pg. 5). Caution, do not over tighten screws.
19) Once power is applied to the cooler the GREEN LED light will illuminate on the bottle ller showing good lter status along with the LCD Bottle Counter.
20) Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. Note: the rst initial dispenses might have air in line
which may cause a sputter. This will be eliminated once all air is purged from the line.
21) Once unit tests out, install Lower Panel back on water cooler(s). Units are now ready for use.
Instructions For Replacing Filters
1) Remove lower cover on cooler by removing (4) screws (See Fig.7, Pg. 5).
2) Turn o󰀨 water supply; dispense water to relieve pressure.
3) Turn used lter counterclockwise 1/4 turn to remove from lter head.
4) Remove cap from new lter and use to seal used lter.
5) Insert new lter into existing lter head and turn fully clockwise. Make sure you can read the label on the front of the lter once it is installed. (See Fig.12 on Pg. 7).
6) Turn on water supply and run a minimum of two gallons of water through the lter to purge air any ne carbon particles from lter. Also run water through bottle ller
Note: Filter status light will automatically reset once new lter is installed.
Page 6
ENLZSTL8WS_1G
1000004543 (Rev. A - 10/18)

Other manuals for Elkay EZF4 1C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elkay EZF4 1C Series and is the answer not in the manual?

Elkay EZF4 1C Series Specifications

General IconGeneral
BrandElkay
ModelEZF4 1C Series
CategoryWater Dispenser
LanguageEnglish

Related product manuals