9
deviated from the program. The thermo-
stat then automatically switches back in
the programmed temperature. To devi-
ate from the comfort temperature follow
the same actions, but instead press
.
4.6 Other settings
The function “CL/HT”
The thermostat can be connected to
a heating system or a cooling system.
The thermostat should be set on “HT”
for a heating system and on “CL” for a
cooling system. If necessary, adjust the
setting by pressing “mode” (15). Then
press “CL/HT” (13) until the desired
mode appears. Exit with “ok” (14).
The function “DLY”
The thermostat optionally can start your
heating system delayed (for a cooling
system, this is set by default). The ther-
mostat only starts your system after it
has been switched off for 5 minutes.
Presson“mode”(15)rsttoenable
the delay. Then press “DLY” (12) until
“DLY” appears on the display and exit
with “ok” (14). To turn off the delay, fol-
low the same procedure but make
sure that “DLY” is not shown in the dis-
play.
The function “1C/2C”
You can set the permissible temperature
uctuationor“span”.Thespandeter-
mines how much the ambient tempera-
ture may increase or decrease before
the thermostat responds. For example:
with a span of 1°C and a comfort tem-
perature set to 20°C, the temperature
maydecreasetoamaximumof19.5°C
(for a heating system) or increase to
20.5°C (for a cooling system) before the
thermostat responds. To set the span,
rstpress“mode”(15)andthenpress
“1C/2C” (11) until you see the desired
span in the display. Exit with “ok” (14).
5 Malfunctions
Malfunction Cause Solution
Information on the
display is not visible
- Batteries are empty
- Batteries placed wrong
- Replace
Strange characters
on display
- Failure in software - Press the
reset key
Temperature is not
well regulated
- Thermostat is too close to a heat source,
exposed to the sun or draught
- The span is set too wide
- Set the span to 1 °C
- Move the
thermostat
6Technicalspecications
6.1Generalspecications
Product description
Name: Programmable room thermostat
Model/Type: KT100
Technicalproductspecications
Batteries: 2 penlight alkaline type
AA/ LR6
Switching Voltage: 24V AC and 230V
AC
Switching Current: max. 6 Amp
Measuring Range: 0 .... 40°C
Adjustable Range: 5 ... 30°C
Measuring Accuracy: +/- 0.5°C
Temperature span: 1°C or 2°C
adjustable
Programs:10presets,10tobemodied