5www.elsema.com
240VAC Supply Supplyconnectiontopowerthe240S1andthemotor
Open MotorOPENdirectionterminal
Close MotorCLOSEdirectionterminal
Neutral Motorneutralterminal
Motor Capacitor Motorcapacitorterminal
Auxiliary Output Usedtoconnectalockorcourtesylight.RelayContacts,CommonandNormallyOpen
Limit Switch Open &
Common
Iflimitswitchesareusedconnectthemtothisterminal.
FactoryDefaultNormallyClosed
Limit Switch Close Iflimitswitchesareusedconnectthemtothisterminal
Push Button Usedtoconnectanexternalpushbuttontooperatethegateordoor.Normallyopeninput.
Open Only
Usedtoconnectanexternalpushbuttontoopenthegateordoor.Withthisinputgateordoor
cannotbeclosed.Holdingthisinputwillpreventclosing.NormallyOpeninput.
Close Only
Usedtoconnectanexternalpushbuttontoclosethegateordoor.Withthisinputgateordoor
cannotbeopened.Holdingthisinputwillpreventopening.NormallyOpeninput.
Common
Commonterminalforanyoftheinputs,includingpushbutton,openonly,closeonly,stop
andpedestrianaccess.
Stop
Usedtoconnectanexternalpushbuttontostopthegateordoor.Holdingthisinputwill
preventthegateordoorfromopeningorclosing.NormallyOpeninput.
Pedestrian Access
Usedtoconnectanexternalpushbuttontoopengateordoorpartiallyforpedestrianaccess.
NormallyOpeninput.
Photo Electric Beam
Usedtoconnectaphotoelectricbeam.FactoryDefaultisNormallyClosedinput.Usercan
changetoNormallyOpen.
DC Output
24VDC/150mA.Usetosupplyaccessories.
(UseElsemaReg12toconvertthisoutputto12VDC)
Slide Switch Usedtoaccessthecontrolcardfeatures.
Input Status LEDs Indicatesinputsstatus.
Tact Switches
TestbuttonforinputsinRUNmodeandusedtoaccessthefeaturesinprogrammode.
A=PushButton
B=OpenOnly
C=CloseOnly
D=Stop
E=PedestrianAccess
Auto Close trimpot UsedtoadjusttheAutoClosetime.
Dip Switch Usedtoaccessthecontrolcardfeatures.
Open, Close LEDs IndicatesOpeningorClosingcycle.
Enter button Usedtochangefeaturesinprogrammingmode.
Receiver
UsedtoconnectElsema’sreceiverstooperatethecontrolcardwitharemotecontrol.Use
Elsema’sPentacodeseries.
Antenna Usedtoconnectanexternalantennaforthepluginreceiver.
Buzzer Indicatesthatchangeoffeatureswassuccessful.
Fuse
Slowblow5Ampsfuse.Replacefusewithaslowblow10Ampsifusingamotorlargerthan
1.0kW(1.3HP).