7www.elsema.com
240VAC Supply Supplyconnectiontopowerthe240S2andthemotor
Open MotorOPENdirectionterminal
Close MotorCLOSEdirectionterminal
Neutral Motorneutralterminal
Motor Capacitor Motorcapacitorterminal
Auxiliary Output Usedtoconnectalockorcourtesylight.RelayContacts,CommonandNormallyOpen
Limit Switch Open &
Common
Iflimitswitchesareusedconnectthemtothisterminal.
FactoryDefaultNormallyClosed
Limit Switch Close Iflimitswitchesareusedconnectthemtothisterminal.
Push Button Usedtoconnectanexternalpushbuttontooperatethegateordoor.Normallyopeninput.
Open Only
Usedtoconnectanexternalpushbuttontoopenthegateordoor.Withthisinputgateordoorcannotbe
closed.Holdingthisinputwillpreventclosing.NormallyOpeninput.
Close Only
Usedtoconnectanexternalpushbuttontoclosethegateordoor.Withthisinputgateordoorcannotbe
opened.Holdingthisinputwillpreventopening.NormallyOpeninput.
Common
Commonterminalforanyoftheinputs,includingpushbutton,openonly,closeonly,stopandpedestrian
access.
Stop
Usedtoconnectanexternalpushbuttontostopthegateordoor.Holdingthisinputwillpreventthegateor
doorfromopeningorClosing.NormallyOpeninput.
Pedestrian Access
Usedtoconnectanexternalpushbuttontoopengateordoorpartiallyforpedestrianaccess.NormallyOpen
input.
Photo Electric Beam
Usedtoconnectaphotoelectricbeam.FactoryDefaultisNormallyClosedinput.Usercanchangeto
NormallyOpen.
DC Output 24VDC/150mA.Usetosupplyaccessories.(UseElsemaReg12toconvertthisoutputto12VDC)
Common CommonterminalforKeySwitch(NCType)
Auto Autoterminalforkeyswitch.Motorwillbecontrolledbyremotecontrol
Manual Manualterminalforkeyswitch.MotorwillbecontrolledbyOpen,CloseandStoppushbuttons.
Tact Switches
TestbuttonforinputsinRUNmodeandusedtoaccessthefeaturesinprogrammode.
A=PushButton
B=OpenOnly
C=CloseOnly
D=Stop
E=PedestrianAccess
Slide Switch Usedtoaccessthecontrolcardfeatures.
Auto Close trimpot UsedtoadjusttheAutoClosetime.
Dip Switch Usedtoaccessthecontrolcardfeatures.
Open, Close LEDs IndicatesOpeningorClosingcycle.
Enter button Usedtochangefeaturesinprogrammingmode.
Receiver
UsedtoconnectElsema’sreceiverstooperatethecontrolcardwitharemotecontrol.UseElsema’s
Pentacodeseries.
Antenna Usedtoconnectanexternalantennaforthepluginreceiver.
Buzzer Indicatesthatchangeoffeatureswassuccessful.
Fuse
Slowblow5Ampsfuse.Replacefusewithaslowblow10Ampsifusingamotorlargerthan1.0kW
(1.3HP).