EasyManua.ls Logo

Elster Instromet RABO G65 - User Manual

Elster Instromet RABO G65
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Instromet
RABO
®
Rotary Gas Meter
Instruction Manual
Question and Answer IconNeed help?

Do you have a question about the Elster Instromet RABO G65 and is the answer not in the manual?

Summary

General Information

Intended Use and Application

Specifies the types of clean, dry, non-corrosive common gases suitable for Elster RABO meters.

Operating Principle

Explains the positive displacement mechanism of the RABO meter using counter-rotating impellers.

Receiving, Handling and Storage

Installation

Piping Configurations

Details horizontal and vertical piping configurations, recommending top inlet for contaminant flow.

Mounting

Adding Oil

Start-up;Commissioning

Decommissioning and Removal

Inspection and Maintenance

Testing

Proving

Describes meter proving using reference devices and requirements for on-site testing.

Differential Pressure Testing

Technical Data

Performance

Presents technical performance specifications like rangeability, start/stop rates, and DP at 100% flow.

Sizing Chart

Provides a chart to select the appropriate meter based on flow rate and operating pressure.

Dimensions and Weights

Index

Rotatable

Describes the rotatable nature of the odometer-style index for desired reading angles.

How to Read

Explains how to read the odometer index and apply the multiplication factor for total volume.

How to Clock a Meter

Details the method to calculate instantaneous flow rate using the index's test dial and a stopwatch.

Removal, Installation and Replacement

Pulser

Thermowell

Installing a Thermowell

Provides step-by-step instructions for installing a thermowell into the meter's auxiliary ports.

Auxiliary Equipment Mounting

Troubleshooting

Elster Instromet RABO G65 Specifications