5.6.4 CSA Certified
The explosion proof housing has the following CSA certification information:
Explosion proof for Class I, Division 1, Group B, C and D T6
Ex d ia [ia] IIB + H2 T6
-50 °C < Tamb < +60 °C
Type 4X
IP66
CSA 13.70001043
Installation requirement: Seal all conduit within 1.50 inches in group
B & C
Warnings:
o Substitution of components may impair intrinsic
safety.
o Read Instruction Manual (Control Drawing:
03.304.001.004.05/2) before operating device. See
UFM Series 6 Safety Instructions (listed in
Appendix I References) for the control drawing.
Figure 5-9: Example of a CSA Label