3 How to Operate DELTA OP
Users Guide '(/7$23 13
*UDSKLF'LVSOD\
The graphic display is an important part of the fire alarm systems user
interface, and is divided in following specific areas:
*UDSKLFV$UHD²OLQHV
The two upper lines display the actual type of alarm, if any.
0HQX$UHD²)LUVW$ODUPDQG6FUROO$UHDOLQHV
1RUPDO0RGH
These two lines are used by the system for general communication with the
user via the hierarchical menu system.
$ODUP0RGH
When in alarm mode the panel displays the 1
st
reported alarm.
When several alarms are detected, the user can scroll through the rest of the
alarms while the most recent is locked on lines 6 & 7.
Line 3 displays the programmable display text assigned to the detector in alarm.
Line 4 indicates the address of the detector in alarm, its type, its zone number and
the time & date the alarm was detected.
The menus are still accessible while in alarm mode.
6WDWLVWLFV$UHD²OLQH.
Depending on the panels mode of operation, this area shows the actual number
of detected ILUHRUIDXOWDODUPV and the number of loop components and outputs
which are disconnected.
0RVWUHFHQW$ODUP$UHD²OLQHV
When in alarm mode of operation, these two lines display the most recent alarm.
Line 6 displays the programmable display text assigned to the detector in alarm.
Line 7 indicates the address of the detector in alarm, its type, its zone number and
the time & date the alarm was detected
'DWH7LPH$UHD²OLQH
The actual time & date is displayed on this line. It is also used to display the
isolation status of the $ODUP7UDQVPLWWHU and $ODUP'HYLFHV.
([DPSOHRI'LVSOD\LQ$ODUP0RGH
The figure below shows '(/7$23 in fire alarm mode (3 reported alarms).
Lines 6 & 7 show the location of the detector/monitor reporting the most recent
fire alarm (room 1435). The detector address is 0102, assigned to zone 1, while
the alarm has been detected at 23.55 hours, December 31st
Three minutes later, while still in alarm mode, the user has pressed the PHQX
key (M), so the PDLQPHQX is displayed on line 3 & 4.
1
2
3
4
5
6
7
8
Line number on display
)LUH$ODUP
Main: 1: SCROLLFAULT/ISOLATION
2: ISOLATE/DESOLATE 3: TEST 4: SYSTEM INFO
No. of Zones in Alarm: 03, Al. No.: 03 of 03
ROOM 1435, 3
RD
FLOOR, WEST BLOCK
ALARM DET.: 0102, ID ZONE: 01 23:55 31/12
Remote Alarm Output Isolated: 23:58 31/12/1997
Graphics Area
Menu Area for:
Main Menu
1
st
Alarm
Scroll Data
Statistics Area
Most recent Alarm
Data Area for:
Systems Date & Time
Isolated Units Status