EasyManuals Logo

Elvox 12F3 User Manual

Elvox 12F3
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
21
C
A
B
1
E+
FP
E-
2
M
CH
+12
21
12
1
2
5
4
6P
+
-
6S
T1
T2
C
VIDEO
T4
A
B
T3
M
V3
A
C
B
4
12
2
3
1
13
OUT
IN
2A OUT 1A2B 1B
4B3B 4AIN3A
T2
T3 T4
TOUT
100
50
B
A
C
E-
2
2
1
E+
1
12V
CH
FP
M
C
A
B
1
E+
FP
E-
2
M
CH
+12
+I+U-
PRI
1C 2C2B1A 1B2A
2112
C
13
1
3
2
12
4
V3
M
B
C
A
C
A
B
FP
E-
M
1
E+
2
CH
+12
12
IN
21
OUT
2D1D
BA
C
A
B
1
E+
FP
E-
2
M
CH
+12
+I+U-
PRI
B
A
C
E-
2
2
1
E+
1
12V
CH
FP
M
4
T2
5
6S
T1
2
1
A
T4
-
+
C
B
VIDEO
T3
6P
4
T2
5
6S
T1
2
1
A
T4
-
+
C
B
VIDEO
T3
6P
1
2
1
E+
FP
E-
2
M
CH
+12
M
V3
A
C
B
4
12
2
3
1
13
B
A
C
C
A
B
+12
CH
M
2
E-
FP
E+
1
+I+U-
PRI
21
E-
2
2
1
E+
1
12V
CH
B
A
C
FP
M
X
X
X
X
X
X
X
X
X
N- Art. 692D
N2- Art. 692D/2
K
K
K
K
K
K
K
K
K
K
K
B4
B4
B4
B5
B5
B5
B1
B2
B3
B0
B0
B0
B1
B3 B2
B1
B3
B2
G- Art. 6923
G- Art. 6923
G- Art. 6923
*
*
*
*
*
*
*
*
*
*
*
*
*
Mains
Mains
Mains
K
K
*
B6
K
X
B6
K
B6
*
si638
X
Video door entry system cable riser wiring. The
video door entry units (interphones) can be connec-
ted to the cable riser in the following ways:
in-out connection, without the aid of floor distri-
butors;
connection with passive distributor type 692D;
connection with active distributor type 692D/2;
hybrid connection using the above 3 methods.
In a video installation, device termination must be
carried out using the jumpers (ABC) in the device it-
self. See the notes below for terminating devices at
the cable riser in accordance with the wiring type.
LEGEND:
B0 - Wide Touch series door entry monitor type 7311
B1 - 7200 series door entry monitor type 7211
B2 - 6600 series door entry monitor
type 6621, 662C, 6721
type 6611, 661C, 6711
B3 - 6800 series door entry monitor
type 6801, type 68MV + 68M1
B4 - Petrarca series door entry monitor
type 6029/C + 6209 + 6145
type 6029 + 6209 + 6145
B5 - Giotto series door entry monitor
type 6329, 6329/C
B6- Tab series door entry monitor
type7529, 7529/D
G - Additional power supply unit type 6923
N - Distributor type 692D
K - Door call button
X- Cable type 732H, 732I (Twisted Pair)
Monitor cable riser
Monitor cable riser
Monitor cable riser
*
CONNECTION OF MONITORS WITH AND WITHOUT FLOOR DISTRIBUTOR TYPE 692D AND 692D/2 (REF. si638).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elvox 12F3 and is the answer not in the manual?

Elvox 12F3 Specifications

General IconGeneral
BrandElvox
Model12F3
CategoryIntercom System
LanguageEnglish