Cabling and Amplifier Selection
The EMS Series products are designed to be used with professional power amplifiers providing the following power
outputs:
EMS-81 500W/channel into eight ohms
EMS-121 700W/channel into eight ohms
EMS-152 1200W/channel into eight ohms
EMS-215 1600W/channel into four ohms
It is good practice to use an amplifier equal to the program power rating of the loudspeaker – so as to retain
sufficient headroom and good dynamic range. Care should be taken during operation to avoid amplifier clipping –
as this can cause serious damage to your loudspeakers. If in doubt, please contact your dealer who will be happy
to assist you in correct amplifier choice and setup.
Cabling
All EMS Series products are supplied with Neutrik Speakon
TM
NL4 connectors, wired pin 1+/1-. It is recommended
that the resistance of your cable is less than one tenth of the nominal system impedance. Given below are the
recommended maximum cable lengths for different cross-sections and impedances.
Conductor Cross Sectional Area Maximum Recommended Cable Length
4 ohms 8 ohms 16 ohms
1.0mm
2
11m 22m 44m
1.5mm
2
17m 34m 68m
2.0mm
2
22m 44m 88m
2.5mm
2
29m 58m 116m
4.0mm
2
44m 88m 176m
6.0mm
2
66m 132m 264m
A small power amplifier working too hard is more likely to damage a loudspeaker than a large power amplifier