Introduction 
880 Operation Manual Issue 7  EMC INDUSTRIAL GROUP LTD  Page 5 of 25  
Introduction 
About this manual 
This manual is divided into several main sections to help find specific information 
quickly.  For  example,  to  find  detailed  information  about  the  different  methods  of 
starting a firing see Start a Firing, page 9. 
A good way to know the EMC 880 once the controller has been installed, as de-
tailed in section Installation, page 19, is simply to try it.  
Turn on power and follow the simple step by step procedure in the section called 
Quick Firing Guide, page 6. 
As questions arise about the controllers operation refer to the appropriate section 
in this manual. 
Please Read 
Before the kiln is fired for the first time it is very important to check the input of the 
controller matches the thermocouple used. 
If these do not match the kiln may over fire and cause a melt down. For instance 
the kiln will over fire if the controller is set for a type K thermocouple but a type R 
thermocouple is used. 
To check controller:    
Watch the display for the input sensor type when power is turned on as de-
tailed in Power Up Test, page 13. To change the controller to another input 
sensor type refer to Field Settings, page 22. 
To check thermocouple:  
See if the type code is written on the probe, i.e. look under the terminal cover, 
otherwise consult kiln supplier. 
Check ambient temperature: 
  After the power up test sequence check controller is showing ambient air tem-
perature, which normally is about 20°C to25°C. 
As a precautionary measure the first firing should be observed to ensure firing pro-
gresses as expected.