Quick Firing Guide
880 Operation Manual Issue 7 EMC INDUSTRIAL GROUP LTD Page 6 of 25
Quick Firing Guide
Follow the procedure below to program the controller for a Bisque firing, stored as
Program 1, and then start the firing.
Establish Firing Program
Draw the temperature profile required and write down program values as shown on
the diagram and chart below, and then enter these values into the controller.
Store a Bisque Firing as Program 1
Step Action Display
1. Press MENU key. Display shows currently selected program.

 ?
2. Set program number  in large display with the UP or DOWN keys.


3. Press NEXT key and set Stage 1 Ramp to .


4. Press NEXT key and set Stage 1 Temperature to .


5. Press NEXT key and set Stage 1 Hold to .


6. Press NEXT key and set Stage 2 Ramp to .


7. Press NEXT key and set Stage 2 Temperature to .


8. Press NEXT key and set Stage 2 Hold to .


9. Press NEXT key and set Stage 3 Ramp to .


10. Press NEXT key and set Stage 3 Temperature to .


11. Press NEXT key and set Stage 3 Hold to .


12. Press EXIT to return to normal operation and show ambient temperature.


Start Bisque Firing Instantly
1. Check small display shows program you want to use, in this case program 1.


2. Press RUN STOP key to start firing.


Delay Start Bisque Firing By 3 Hours
1. Check small display shows program you want to use, in this case program 1.


2. Press RUN STOP key and while light is flashing set large display to .

Firing Type Bisque Program Number 1
RAMP TEMP HOLD
STAGE 1
50°C per hr 150°C none
STAGE 2
100°C per hr 650°C none
STAGE 3
150°C per hr 950°C 15 min
RAMP
RAMP 150°C/hr
RAMP 50°C/hr
TEMP 150°C
TEMP 650°C
TEMP 950°C
STAGE 1
STAGE 2
STAGE 3
TEMPERATURE
HOLD 15 minutes

Table of Contents