EasyManua.ls Logo

EMC VNX5500 - Page 18

EMC VNX5500
122 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18 VNX5500 Hardware Information Guide
System component description
Table 5 describes the Control Station LEDs.
Table 5 Control Station LEDs
LED Color State Description
System status/boot
(location 2)
Green On Power on/system loaded and
ready
Blinking Booting up
1
or system degraded
Amber On Critical, non-recoverable error;
system has failed due to:
• Themtrip asserted
• IERR asserted
• Non-recoverable temperature
threshold asserted.
• Non-recoverable voltage
asserted.
• Power fault/Power control
failure
Blinking Non-fatal alarm; system is likely
to fail due to:
• Critical temperature threshold
asserted.
• Critical voltage threshold
asserted.
• Critical fan threshold
asserted.
—Off Power off
System power/sleep or
standby (location 3)
Green On Power on
Blinking Sleep (standby)
—Off Power off
Internal hard drive activity
(location 4)
Green Blinking Hard drive access
— Off No hard drive activity
Onboard (integrated)
Ethernet NIC 1 and 2
(locations 5 and 6,
respectively)
Green On NIC link/no access
Blinking NIC link/LAN access
1. The system status LED flashes green while booting up.