EasyManua.ls Logo

EMC2 Data Domain DD2500 - I;O modules and slot assignments; FC I;O module option; Ethernet I;O module options; Internal system components

EMC2 Data Domain DD2500
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
I/O modules and slot assignments
See DD2500 slot assignments on page 10 for the I/O module slot assignments of the
system.
Table 2 DD2500 slot assignments
Slot Number DD2500 System
0 FC, Ethernet or empty
1 FC, Ethernet or empty
2 FC, Ethernet or empty
3 SAS or empty
4 NVRAM-BBU
When a DD2500 system is upgraded, the newly inserted I/O module should go into the
next available slot position. The following slot loading rules apply:
l
For mixed populations, populate all Ethernet I/O modules first, then populate the FC
I/O modules.
l
For Ethernet I/O modules, populate the leftmost (slot 0) slot first, if empty, then slot 1
and so on.
l
Slot 3 is reserved for SAS I/O modules only.
FC I/O module option
The FC I/O module is a dual-port Fibre Channel module. The optional virtual tape library
(VTL) feature requires at least one FC I/O module. Three FC I/O module slots are available
for use.
Ethernet I/O module options
The following Ethernet I/O modules are available:
l
Dual Port 10GBase-SR Optical with LC connectors
l
Dual Port 10GBase-CX1 Direct Attach Copper with SPF+ module
l
Quad Port 1000Base-T Copper with RJ-45 connectors
l
Quad port 2-port 1000Base-T Copper (RJ-45)/2-port 1000Base-SR Optical
You can use up to three I/O module slots for Ethernet connectivity.
Internal system components
The photo shows the system with the storage processor (SP) module removed from the
chassis. The top of the photo shows the rear of the system.
Installation and Setup Guide
10 Installation and Setup Guide

Related product manuals