Description
Gas or Oil Heat Yes
Electric Furnace Yes
Heat Pump (No Aux. or Emergency Heat) Yes
Heat Pump (with Aux. or Emergency Heat) No
Systems with up to 3 Stages Heat, 2 Stages Cool No
Heat Only Systems Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces Yes
Cool Only Systems Yes
Hydronic (Hot Water) Zone Heat – 2 Wires Yes
Hydronic (Hot Water) Zone Heat – 3 Wires Yes
www.white-rodgers.com
Blue Selecto Thermostat with
Automatic Heat/Cool Changeover Option
PART NO. 37-6952B
Replaces 37-6952A
0905
Single Stage or Heat Pump
Installation and Operating Instructions for Model:
APPLICATIONS
THERMOSTAT APPLICATION GUIDE
1F80ST-0471 Thermostat
with Spanish Display
SPECIFICATIONS
Electrical Rating:
Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45° to 90°F (7° to 32°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) . . . . . . . . . . . . . . . . . . . . . Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient. . . . . . . . . . . . . . . . . . . . . . . . . . 32° to +105°F (0° to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . . . . . -40° to +150°F (-40° to +65°C)
Dimensions Thermostat. . . . . . . . . . . . . . . . . . . . . . 3.4"H x 4.4"W x 1.3"D
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or circuit
breaker box until installation is complete.
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this
product may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to www.white-rodgers.com for location to
send product containing mercury.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
Model Programming Choices
1F80ST-0471
5/2 Day 5/1/1 Day Non-Programmable
1F86ST-0471
Non-Programmable
Save these instructions for future use!
Index Page
Installation 2
Wiring Connections 3
Thermostat Quick Reference 3
Installer Confi guration Menu 4
Operating Your Thermostat 6
Programming 6
Troubleshooting 8

Questions and Answers

  • M
    Matthew MaddoxJul 30, 2025
    What to do if my Emerson Thermostat has no heat?
    • R
      Robin ClineJul 31, 2025
      If your Emerson Thermostat isn't producing heat, try these steps: * Ensure the pilot light is lit. * If the heat works intermittently, contact the furnace manufacturer or a local HVAC service person for assistance, as it may be a furnace lock-out condition. * If the thermostat doesn't click after being reset, contact your heating and cooling service person or the place of purchase for a replacement, as the heating system may require service or the thermostat may need replacing.
  • J
    Jason WebbAug 5, 2025
    How to fix Emerson Thermostat when the setting and thermometer disagree?
    • C
      crystal22Aug 6, 2025
      If the temperature shown on your Emerson Thermostat doesn't match the actual room temperature, you can adjust the thermometer setting by +/- 4 degrees. Refer to the Temperature Display Adjustment section in the Configuration Menu.
  • S
    Sarah HerreraAug 11, 2025
    How to troubleshoot Emerson 1F86ST-0471 Thermostat with no heat, no cool, or no fan?
    • J
      Jason CobbAug 11, 2025
      If your Emerson Thermostat isn't heating, cooling, or running the fan, check the following: * Ensure the fuse isn't blown or the circuit breaker isn't tripped; replace the fuse or reset the breaker if needed. * Verify the furnace power switch is turned ON. * Make sure the furnace blower compartment door or panel is correctly installed to engage the safety interlock or door switch. * Check for and tighten any loose connections to the thermostat or system.
  • A
    alvarezheidiAug 18, 2025
    Why does my Emerson Thermostat heat, cool, or fan run constantly?
    • T
      Thomas JacobsonAug 18, 2025
      If your Emerson Thermostat causes the heat, cool, or fan to run constantly, the issue might be due to: * A short in the wiring: Inspect each wire connection to ensure they are not shorted or touching. * A short in the thermostat: Try resetting the thermostat. * A short in the heat/cool/fan system: If the system then operates correctly, replace the thermostat. * The VENT switch being set to VENT ON: Try resetting the thermostat.
  • R
    Richard HernandezAug 23, 2025
    Why does my Emerson Thermostat cycle too fast?
    • A
      Ashley StantonAug 23, 2025
      If your Emerson Thermostat causes the furnace (or air conditioner) to cycle too fast or too slow, it might be influenced by the location of the thermostat or the size of the heating system. To increase the cycle time, select 'bA' for slow cycle in the Configuration menu, step 6 (heat), 7 (cool), or 8 (heat pump).

Summary

Installation

Remove Old Thermostat

Steps for removing the existing thermostat from the wall.

Installing New Thermostat

Instructions for mounting the new thermostat base and body.

SS;HP Switch Configuration

Setting the switch for conventional or heat pump systems.

Gas;Elec Switch Configuration

Setting the switch for gas or electric heating fan control.

Battery Installation

Guide for installing and replacing the thermostat batteries.

Wiring Connections

Installer Configuration Menu

Reversing Valve Output

Configures the O/B terminal for heat pump changeover.

Program Options (1 F80 only)

Sets programming mode: 5/2 day, 5/1/1 day, or non-programmable.

Frio Ahorro (Cool Savings)

Enables and sets the level for energy-saving cool adjustments.

Operating Your Thermostat

Vent Setting Options

Choosing between Auto or On for the fan operation.

System Mode Selection

Setting the system to Heat, Cool, Off, or Auto changeover.

Manual Operation

Bypassing the program for manual temperature adjustment.

Programming (For Programmable Model Only)

Energy Saving Factory Pre-Program

Overview of the default heating and cooling schedule.

Planning Your Program

Guidelines and worksheet for setting custom schedules.

Troubleshooting

Reset Operation

Procedure to reset thermostat settings to factory defaults.

Common Symptoms and Corrections

Diagnosing and fixing issues like no heat, no cool, or constant operation.