This thermostat is intended for use with a low voltage NEC
Class II system. Do not use this thermostat with a line voltage
system. If in doubt about whether your wiring is millivolt, line,
or low voltage, have it inspected by a qualified heating and air
conditioning contractor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could
cause the control to malfunction.
Blue 2” Single Stage Thermostat
Installation and Operating Instructions
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
APPLICATIONS
For use with the following Class II systems:
• SingleStagesystems
• Single-stageheatpumpsystemswithnoAuxheat
DO NOT USE WITH:
• Systemsexceeding30VACand1.5amps
• 3-wirezonedhydronicheatingsystems
1F86-0244 Thermostat
Model Programming Choice
1F86-0244
Non-Programmable
SPECIFICATIONS
Electrical Rating:
BatteryPower ................................................. mVto30VAC,50/60HzorDC
Input-Hardwire ................................................ 20to30VAC
Terminal Load ........................................................ 1.0Aperterminal,1.5Amaximumallterminalscombined
SetpointRange ...................................................... 45°to90°F(7°to32°C)
Differential(SingleStage) ...................................... Heat0.6°F;Cool1.2°F(adjustable)
Differential(HeatPump) ........................................ Heat1.2°F;Cool1.2°F(adjustable)
Operating Ambient ................................................. 32°to+105°F(0°to+41°C)
OperatingHumidity ................................................ 90%non-condensingmax.
ShippingTemperatureRange ................................ -40°to+150°F(-40°to+65°C)
Dimensions Thermostat ......................................... 3-3/4”Hx4-3/4”Wx1-1/2”D
PRECAUTIONS
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could cause
a fire hazard.
WARNING
!
www.white-rodgers.com
PART NO. 37-7010C
Replaces37-7010B
1004

Questions and Answers

  • M
    Michael CarterJul 26, 2025
    How to fix an Emerson 1F86-0244 that is not heating?
    • W
      wcarterJul 26, 2025
      If your Emerson Thermostat isn't heating, make sure the System Switch is set to Heat and raise the setpoint above the room temperature. Also, check that the thermostat and system wires are securely attached. If the thermostat doesn't click after being reset, contact a heating and cooling service person or the place of purchase for a replacement.
  • T
    Tonya SheppardJul 30, 2025
    What to do if Emerson 1F86-0244 Thermostat display is blank and the keypad isn't responding?
    • D
      Dana MercadoJul 30, 2025
      If your Emerson Thermostat displays nothing or the keypad isn't responding, it might be due to a voltage spike or static discharge. Try performing the Reset Operation.
  • K
    Kevin KelleyAug 3, 2025
    How to troubleshoot no heat, no cool, or no fan problems on an Emerson 1F86-0244 Thermostat?
    • V
      vickie54Aug 3, 2025
      If your Emerson Thermostat isn't heating, cooling, or the fan isn't working, check these potential causes: * A blown fuse or tripped circuit breaker: Replace the fuse or reset the breaker. * The furnace power switch is OFF: Turn the switch to ON. * The furnace blower compartment door or panel is loose: Replace the door panel correctly to engage the safety interlock or door switch.
  • J
    James FitzgeraldAug 8, 2025
    Why does my Emerson 1F86-0244 heat, cool, or fan run constantly?
    • K
      Katherine NortonAug 8, 2025
      If your Emerson Thermostat always runs heat, cool or fan, there might be a short in the wiring. Check each wire connection to make sure they aren't shorted or touching. Try resetting the thermostat. If the problem continues, the manufacturer of your system or a service person can give you instructions on how to test the Heat/Cool/Fan system for correct operation.
  • A
    Alexandra GrossAug 12, 2025
    What to do if my Emerson 1F86-0244 Thermostat is not cooling?
    • J
      Jonathan BentonAug 12, 2025
      If your Emerson Thermostat isn't cooling, ensure the System Switch is set to Cool and lower the setpoint below the room temperature. Verify that the thermostat and system wires are securely attached. If the thermostat still doesn't cool, follow the same diagnostic procedures as for a No Heat condition, but ensure the thermostat is set to Cool and the setpoint is below room temperature.
  • J
    James DunnAug 16, 2025
    How to calibrate the thermometer on an Emerson Thermostat?
    • G
      Gerald RodriguezAug 16, 2025
      If the Emerson Thermostat setting and thermometer disagree, you can adjust the thermometer setting. The thermometer can be adjusted +/- degrees as listed in item 7 of the Configuration Menu.
  • T
    Thomas MorenoAug 21, 2025
    Why is my Emerson 1F86-0244 Thermostat cycling too fast or too slow?
    • D
      Darius CoxAug 21, 2025
      If your Emerson Thermostat cycles too fast or too slow, the location of the thermostat or the size of the heating or cooling system could be the cause. Item 3 (CR Heat) or 4 (CR Cool) in the Configuration Menu is the adjustment that controls the cycle rate.

Summary

APPLICATIONS

SPECIFICATIONS

PRECAUTIONS

WARNING

CAUTION

INSTALLATION

REMOVE OLD THERMOSTAT

Steps for safely removing the existing thermostat unit.

ATTACH THERMOSTAT BASE TO WALL

Instructions for mounting the new thermostat base securely.

O;B TERMINAL SWITCH SELECTION

Guidance on setting the O/B switch for heat pump changeover.

GAS;ELEC SWITCH

How to set the Gas/Electric switch for system type.

BATTERY LOCATION

Information on battery installation and replacement.

ATTENTION! Mercury Handling

Instructions for handling mercury from replaced units.

WIRING DIAGRAMS

THERMOSTAT QUICK REFERENCE

The Thermostat Buttons and Switches

Identifies and explains the function of thermostat controls.

The Display

Explains the symbols and information shown on the thermostat screen.

INSTALLER;CONFIGURATION MENU

OPERATION

CHECK THERMOSTAT OPERATION

Procedures to verify the thermostat functions correctly.

Fan Operation

How to test the fan control functionality.

Heating System

Steps to test the heating system's response.

Cooling System

Steps to test the cooling system's response.

Cooling System Safety Caution

Do not operate cooling below 50°F to prevent damage.

TROUBLESHOOTING

Reset Operation

How to reset the thermostat after power issues or erratic behavior.

Common Troubleshooting Symptoms

Addresses issues like no heat/cool, constant operation, and cycle rates.

Emerson 1F86-0244 Specifications

General IconGeneral
Display TypeDigital
Stages1 Heat/1 Cool
BacklightYes
MountingWall
Compatibilitygas, oil, electric systems
Voltage24 VAC
Temperature Range45°F to 90°F
ProgrammableNon-programmable