Emerson 5301HxxxxxxxxxxxxxxZZ Series User Manual

Emerson 5301HxxxxxxxxxxxxxxZZ
Series
488 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Reference Manual
00809-0100-4530, Rev FA
April 2019
Rosemount
5300 Level Transmitter
Guided Wave Radar

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Emerson 5301HxxxxxxxxxxxxxxZZ Series and is the answer not in the manual?

Emerson 5301HxxxxxxxxxxxxxxZZ Series Specifications

General IconGeneral
CategoryTransmitter
Measurement TypePressure
Accuracy±0.1% of Span
Operating Temperature-40 to 85°C (-40 to 185°F)
Ingress ProtectionIP67
Hazardous Area CertificationsATEX, IECEx, FM, CSA
Stability±0.1% of URL per year
Process Connection1/2" NPT
Communication ProtocolWirelessHART
Range0-1000 bar
Model5301H

Summary

Transmitter overview

Theory of operation

Explains TDR principles, pulse reflection, and distance calculation for level measurement.

Mechanical installation

Mounting considerations

Advises considering specific mounting requirements, vessel, and process characteristics.

Mount device on tank

Details procedures for connecting the transmitter to the tank via flange, loose flange, or threaded connections.

Electrical installation

4-20 mA/HART communication

Details power requirements, load limitations, and wiring diagrams for 4-20 mA/HART communication.

HART to Modbus converter (HMC)

Covers external power supply, signal wiring, and connection terminals for HMC.

FOUNDATION Fieldbus

Details power requirements, connecting fieldbus devices, and wiring diagrams.

Configuration

Basic configuration using Rosemount Radar Master

Provides system requirements and procedures for configuring the transmitter using RRM.

Modbus communication protocol configuration

Details Modbus RTU, ASCII, and Levelmaster communication setups.

Operation

Service and troubleshooting

Diagnostic messages

Lists device status, errors, warnings, and measurement status messages with actions.

Troubleshooting guide

Provides a chart with symptoms, possible causes, and recommended actions for malfunctions.

Service and troubleshooting tools

Covers tools for analyzing measurement signals, echo curves, and adjusting thresholds.

Safety Instrumented Systems (4-20 mA only)

Safety Instrumented System (SIS) certification

Explains SIS certification and requirements for the Rosemount 5300.

Perform proof test for SIS applications

Suggests proof tests for safety functions and provides guidance for selecting appropriate tests.

Specifications and reference data

Performance specifications

Details performance specifications including reference conditions, accuracy, repeatability, and temperature effects.

Configuration parameters

Basic configuration parameters

Describes basic configuration parameters like measurement units and tank/probe geometry.

Advanced configuration

Dynamic Vapor Compensation

Explains dynamic vapor compensation for high pressure steam applications.

Remote mounting

Level Transducer Block

Parameters and descriptions

Lists and describes Level Transducer Block parameters.

Diagnostics device errors

Lists device errors and their corrective actions.

Analog-Input Block

Analog Input block

Description of the AI block and its parameters.

Configure the AI block

Describes required parameters and channel selection for AI block configuration.

Rosemount 5300 with HART to Modbus Converter

Safety messages

Warns about special precautions for personnel safety during HART to Modbus Converter operations.

Related product manuals