8. PARAMETERS IN TABLE FORM
Parameter groups:
Label
Meaning
ST
Display temperature control parameters
DP
Display variables to be shown on the keyboard
CF
Display configuration parameters
SP
Display parameters for machine set up
Sd
Display dynamic set-point parameters
ES
Display energy saving and automatic timed switch-on/off parameters
AH
Display auxiliary heating parameters
CO
Display compressor parameters
SL
Display stepless compressor parameters
PA
Display evaporator/condenser water pump parameters
Pd
Display pump down function parameters
Un
Display unloading function parameters
FA
Display ventilation parameters
Ar
Display anti-freeze heaters parameters
dF
Display defrost parameters
rC
Display heat recovery parameters
FS
Display production of domestic hot water parameters
FC
Display free-cooling function parameters
US
Display auxiliary output parameters
AL
Display alarm parameters
Et
Display parameters for the management of the electronic expansion valve
IO
Display inputs/outputs configuration parameters
CA
Display analog input calibration parameters
RA
Display analog input range parameters
Temperature control
Parameter
Description
min
max
um
Resolution
ST 1
Chiller set point
This allows you to set the working set point in chiller mode
ST02
ST03
°C/°F
Dec/int
ST 2
Minimum chiller set
This defines the minimum limit that can be used for the working set point
in chiller mode
-50.0
-58
ST03
°C
°F
Dec
int
ST 3
Maximum chiller set point
This defines the maximum limit that can be used for the working set point
in chiller mode
ST02
110
230
°C
°F
Dec
int
ST 4
Heat pump set point
This allows you to set the working set point in h.p. mode
ST05
ST06
°C/°F
dec/int
ST 5
Heat pump minimum set point
This defines the minimum limit that can be used for the working set point
in heat pump mode
-50.0
-58
ST06
°C
°F
Dec
int
ST 6
Heat pump maximum set point
This defines the maximum limit that can be used for the working set point
in heat pump mode
ST05
110
230
°C
°F
Dec
int
ST 7
Intervention band regulation steps in chiller mode
0.1
1
25.0
45
°C
°F
Dec
int
ST 8
Intervention band regulation steps in heat pump mode
0.1
1
25.0
45
°C
°F
Dec
int