1592020010 XR10CX GB m&M r1.1 27.03.2015 XR10CX 1/4
Digital controller with cooling or heating action
XR10CX
CONTENTS
1. GENERAL WARNING ___________________________________________________ 1
2. GENERAL DESCRIPTION _______________________________________________ 1
3. CONTROLLING LOADS _________________________________________________ 1
4. FRONT PANEL COMMANDS _____________________________________________ 1
5. MAX & MIN TEMPERATURE MEMORIZATION _______________________________ 1
6. MAIN FUNCTIONS _____________________________________________________ 2
7. PARAMETERS ________________________________________________________ 2
8. DIGITAL INPUT (ENABLED WITH P3P = N) _________________________________ 3
9. TTL SERIAL LINE FOR MONITORING SYSTEMS ___________________________ 3
10. X-REP OUTPUT OPTIONAL ____________________________________________ 3
11. INSTALLATION AND MOUNTING _________________________________________ 3
12. ELECTRICAL CONNECTIONS ____________________________________________ 3
13. HOW TO USE THE HOT KEY _____________________________________________ 3
14. ALARM SIGNALS ______________________________________________________ 3
15. TECHNICAL DATA _____________________________________________________ 3
16. CONNECTIONS _______________________________________________________ 4
17. DEFAULT SETTING VALUES _____________________________________________ 4
1. GENERAL WARNING
1.1 PLEASE READ BEFORE USING THIS MANUAL
This manual is part of the product and should be kept near the instrument for easy and
quick reference.
The instrument shall not be used for purposes different from those described hereunder.
It cannot be used as a safety device.
Check the application limits before proceeding.
Dixell Srl reserves the right to change the composition of its products, even without
notice, ensuring the same and unchanged functionality.
1.2
SAFETY PRECAUTIONS
Check the supply voltage is correct before connecting the instrument.
Do not expose to water or moisture: use the controller only within the operating limits
avoiding sudden temperature changes with high atmospheric humidity to prevent
formation of condensation
Warning: disconnect all electrical connections before any kind of maintenance.
Fit the probe where it is not accessible by the End User. The instrument must not be
opened.
In case of failure or faulty operation send the instrument back to the distributor or to
“Dixell S.r.l.(see address) with a detailed description of the fault.
Consider the maximum current which can be applied to each relay (see Technical Data).
Ensure that the wires for probes, loads and the power supply are separated and far
enough from each other, without crossing or intertwining.
In case of applications in industrial environments, the use of mains filters (our mod. FT1)
in parallel with inductive loads could be useful.
2. GENERAL DESCRIPTION
Model XR10C, format 32 x 74 mm format is a single stage temperature controller suitable for
applications in the field of refrigeration or heating. It provides a relay output to drive the
compressor. It is also provided with 2 NTC or PTC probe inputs, the first one for temperature
control, the second one, optional, to connect to the HOT KEY terminals to signal the
condenser temperature alarm or to display a temperature. The digital input can operate as
third temperature probe.
The HOT KEY output allows to connect the unit, by means of the external module XJ485-CX,
to a network line ModBUS-RTU compatible such as the Dixell monitoring units of X-WEB
family. It allows to program the controller by means the HOT KEY programming keyboard.
The instrument is fully configurable through special parameters that can be easily
programmed through the keyboard.
3. CONTROLLING LOADS
3.1 THE REGULATION OUTPUT
The regulation is performed according to the temperature measured by the probe.
The instruments are provided with the CH programmable parameter which enables the user to
set the regulation both for heating or cooling applications:
· CH = CL: cooling applications
· CH = Ht: heating applications
3.2 CH = CL: COOLING APPLICATIONS.
The Hy value is automatically set above the Set Point. If the temperature increases and
reaches set point plus differential the compressor is started and then turned off when the
temperature reaches the set point value again.
Time
Temper.
Compr.
SET
ON
3.3 CH = HT: HEATING APPLICATION.
The Hy value is automatically set under the Set Point. If the temperature decreases and
reaches set point minus differential the regulation output is activated and then turned off when
the temperature reaches the set point value again.
Time
Temper.
Heating
ON
SET
SET- HY
Time
4. FRONT PANEL COMMANDS
: To display target set point; in programming mode it selects a parameter or confirm
an operation.
(DEF) Not enabled
(UP): To see the max. stored temperature; in programming mode it browses the
parameter codes or increases the displayed value.
(DOWN) To see the min stored temperature; in programming mode it browses the
parameter codes or decreases the displayed value.
To switch the instrument off, if onF = oFF.
Not enabled
KEY COMBINATIONS:
+

To lock & unlock the keyboard.
+ To enter in programming mode.
+ To return to the room temperature display.
4.1 USE OF LEDS
Each LED function is described in the following table.
LED
MODE
FUNCTION
ON
Compressor enabled
Flashing
Anti-short cycle delay enabled
ON
An alarm is occurring
ON
Energy saving enabled
°C/°F
ON
Measurement unit
°C/°F
Flashing
Programming phase
5. MAX & MIN TEMPERATURE MEMORIZATION
5.1 HOW TO SEE THE MIN TEMPERATURE
1. Press and release the n key.
2. The “Lo” message will be displayed followed by the minimum temperature recorded.
3. By pressing the n key again or by waiting 5s the normal display will be restored.
5.2 HOW TO SEE THE MAX TEMPERATURE
1. Press and release the o key.
2. The “Hi” message will be displayed followed by the maximum temperature recorded.
3. By pressing the o key again or by waiting 5s the normal display will be restored.
5.3 HOW TO RESET THE MAX AND MIN TEMPERATURE RECORDED
1. Hold press the SET key for more than 3s, while the max. or min temperature is
displayed. (rSt message will be displayed)
2. To confirm the operation the “rSt” message starts blinking and the normal temperature
will be displayed.
Question and Answer IconNeed help?

Do you have a question about the Emerson Dixell XR10CX and is the answer not in the manual?

Emerson Dixell XR10CX Specifications

General IconGeneral
DisplayLCD
Resolution0.1 °C
Accuracy (at ambient temperature)±0.5 °C
Accuracy±1 °C
Frontal ProtectionIP65
Protection ratingIP65
TypeTemperature Controller
Input TypeNTC
Measuring Range-50°C to +150°C
Power Supply230V AC
Temperature Range-50°C to +150°C

Summary

General Warning

Please Read Before Using This Manual

Important notes and disclaimers for users before operating the instrument. Ensure correct reference.

Safety Precautions

Crucial safety guidelines for installation, operation, and maintenance to prevent hazards.

Controlling Loads

CH = CL: Cooling Applications

Details on how the Hy value functions for cooling applications and compressor control.

CH = HT: Heating Application

Details on how the Hy value functions for heating applications and regulation output.

Max & Min Temperature Memorization

Main Functions

How to Change the Setpoint

Procedure to modify the setpoint value using the front panel keys.

How to Change a Parameter Value

Guide for accessing and modifying parameter values within the controller's menu.

The Hidden Menu

Explanation of how to access and navigate the advanced hidden menu for parameters.

Parameters

Digital Input (Enabled with P3 P = N)

Installation and Mounting

Electrical Connections

How to Use the Hot Key

How to Program a Hot Key from the Instrument (Upload)

Procedure to copy controller settings onto a Hot Key for backup or transfer.

How to Program an Instrument Using a Hot Key (Download)

Procedure to load settings from a Hot Key into the controller.

Alarm Signals

Connections

Related product manuals