1592040000 XR20-30-60-70T EN v1.5 2021.06.22 XR20-30-60-70T 24/41
inP
nPS
Number of external pressure switch alarms
before stopping the regulation
0
Pr2
0 to 15
inP
odC
Compressor and fan status after door
opening
no
Pr2
no(0); FAn(1); CPr(2); F-C(3)
inP
rrd
Regulation restart after door alarm
no
Pr2
n(0); Y(1)
inP
CLi
Light output activation from door input
no
Pr2
n(0); Y(1)
inP
LCi
Time with light output forced ON
(0=function disabled)
0
Pr2
0 to 255 min
inP
n01
Number of motion detections before
activating light output (valid if ixF=EMt)
0
Pr2
0 to 10
inP
t01
Time with light output forced ON after
motion detection
0
Pr2
0 to 255 min
ES
ErA
Energy saving algorithm
nu
Pr2
nu(0); bAS(1)
ES
HES
Energy saving mode temperature
differential
0
Pr1
°C
[-30°C to 30°C]
[-54°F to 54°F]
ES
LdE
Energy saving controls the lights (lights
OFF when energy saving is active)
no
Pr1
n(0); Y(1)
ES
StE
Period to switch from normal mode to
energy saving mode
00:00
Pr1
hh:mm
0 to 23h50min; nu
ES
EtS
Period to switch from energy saving mode
to normal mode
00:00
Pr1
hh:mm
0 to 23h50min; nu
ES
dS
Door opening time to switch from EtS to
StE
0
Pr1
sec
0 to 999 sec
ES
nES
Number of motion detections before
disabling energy saving mode (valid if
ixF=EMt)
0
Pr1
0 to 255
Cnt
n1H
Number of activations for relay output oA1
(thousands of)
Pr1
read only
Cnt
n1L
Number of activations for relay output oA1
(units of)
Pr1
read only
Cnt
n2H
Number of activations for relay output oA2
(thousands of)
Pr1
read only
Cnt
n2L
Number of activations for relay output oA2
(units of)
Pr1
read only
Cnt
n3H
Number of activations for relay output oA3
(thousands of)
Pr1
read only
Cnt
n3L
Number of activations for relay output oA3
(units of)
Pr1
read only
Cnt
n4H
Number of activations for relay output oA4
(thousands of)
Pr1
read only
Cnt
n4L
Number of activations for relay output oA4
(units of)
Pr1
read only
Cnt
n7H
Number of total activations of digital input 1
(thousand of)
Pr1
read only
Cnt
n7L
Number of total activations of digital input 1
(units of)
Pr1
read only
Cnt
n8H
Number of total activations of digital input 2
(thousand of)
Pr1
read only
Cnt
n8L
Number of total activations of digital input 2
(units of)
Pr1
read only
Cnt
F1H
Number of working hours for relay output
oA1 (thousands of)
Pr1
hours
read only
Cnt
F1L
Number of working hours for relay output
oA1 (units of)
Pr1
hours
read only
Cnt
F2H
Number of working hours for relay output
oA2 (thousands of)
Pr1
hours
read only
Cnt
F2L
Number of working hours for relay output
oA2 (units of)
Pr1
hours
read only
Cnt
F3H
Number of working hours for relay output
oA3 (thousands of)
Pr1
hours
read only
Cnt
F3L
Number of working hours for relay output
oA3 (units of)
Pr1
hours
read only

Table of Contents

Other manuals for Emerson Dixell XR70T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Dixell XR70T and is the answer not in the manual?

Emerson Dixell XR70T Specifications

General IconGeneral
BrandEmerson
ModelDixell XR70T
CategoryController
LanguageEnglish

Related product manuals