www.Fisher.com
Fisherr 3582 and 3582i Positioners, 582i
Electro-Pneumatic Converter, and 3583 Valve
Stem Position Transmitters
Contents
Introduction 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scope of Manual 2. . . . . . . . . . . . . . . . . . . . . . . . .
Description 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type Number Descriptions 6. . . . . . . . . . . . . . .
Specifications 6. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Educational Services 6. . . . . . . . . . . . . . . . . . . . . .
Installation 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Special Instructions for “Safe Use” and
Installation in Hazardous Areas for
for 582i Converter 7. . . . . . . . . . . . . . . . . . . . .
CSA 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ATEX 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IECEx 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NEPSI 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INMETRO 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Changing Cam Position 14. . . . . . . . . . . . . . . . . .
Pressure Connections 15. . . . . . . . . . . . . . . . . . . .
Supply Connection 15. . . . . . . . . . . . . . . . . . . . .
Output Connection 15. . . . . . . . . . . . . . . . . . . . . .
Instrument Connection 15. . . . . . . . . . . . . . . . . .
Diagnostic Connections 16. . . . . . . . . . . . . . . . .
Vent 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Connections for 3582i
Valve Positioner 18. . . . . . . . . . . . . . . . . . . . . . .
582i Converter Installation 19. . . . . . . . . . . . . . . .
Operating Information 20. . . . . . . . . . . . . . . . . . . . .
Valve Positioner Cam Information 20. . . . . . . . . .
Valve Stem Position Transmitter Cam
Information 21. . . . . . . . . . . . . . . . . . . . . . . . . . .
(continued on page 2)
CONTROL VALVE WITH
3582i POSITIONER
CONTROL VALVE WITH
3583 TRANSMITTER
CONTROL VALVE WITH
3582 POSITIONER
W5498-1
W8424
W5499-1
Figure 1. Typical Mounting for Fisher 3582 and 3582i Positioners and 3583 Transmitters
Instruction Manual
D200138X012
June 2010
3582, 582i, and 3583
Question and Answer IconNeed help?

Do you have a question about the Emerson Fisher 3582 and is the answer not in the manual?

Emerson Fisher 3582 Specifications

General IconGeneral
BrandEmerson
ModelFisher 3582
CategoryValve Positioners
LanguageEnglish

Summary

Specifications for Valve Positioners

Performance

Details linearity and hysteresis for positioners.

Specifications for Valve Stem Position Transmitters

Hazardous Area Classification for 3583

Specifies ATEX Group II Category 2 Gas and Dust compliance for 3583.

Special Instructions for Safe Use and Installation in Hazardous Locations

ATEX Standards and Conditions

Changing Cam Position

Electrical Connections for 3582i Valve Positioner

582i Converter Installation

Valve Positioner Cam Information

Valve Stem Position Transmitter Cam Information

Changing Valve Positioner Action

Changing Valve Stem Position Transmitter Action

Calibration

Beam Alignment

Procedures to ensure correct mechanical alignment before calibration.

Calibration Steps

Detailed steps for performing calibration after beam alignment.

Principle of Operation

Maintenance

Changing the Range Spring

Loop Schematics and Nameplates