EasyManua.ls Logo

Emerson Rosemount 5300 Series - Configure; Configure using Rosemount Radar Master; Configure using AMS Device Manager or handheld communicator

Emerson Rosemount 5300 Series
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Data Sheet
00813-0100-4530, Rev DA
December 2010
Rosemount 5300 Series
22
Temperature and Pressure Limits
Ambient Temperature The maximum and minimum ambient temperature for the electronics depends on the process
temperature (as described by the graph below) and on the approval (see “Product Certifications” on
page 36).
Note:
Nozzle insulation for the HTHP version (Operating Temperature and Pressure code H) should
not exceed 4 in. (10 cm)
The temperature range for the optional Integral Display is -4 °F to 158 °F (-20 °C to 70 °C)
In applications where the ambient temperature exceeds the limits of the electronics, a Remote
Mounting connection can be used. The maximum temperature for the Remote Mounting
connection at the vessel connection point is 302 °F (150 °C)
Storage Temperature -58 °F to 194 °F (-50 °C to 90 °C)
With Integral Display: -40 °F to 185 °F (-40 °C to 85 °C)
-320 (-196)
-40 (-40)
-40 (-40)
-17 (-27)
Ambient Temperature °F (°C)
Process Temperature °F (°C)

Other manuals for Emerson Rosemount 5300 Series

Related product manuals