EasyManua.ls Logo

Emerson Rosemount 5300 Series - Canada; E6 Explosionproof, Dust-Ignitionproof

Emerson Rosemount 5300 Series
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Data Sheet
00813-0100-4530, Rev DA
December 2010
31
Rosemount 5300 Series
Physical Specification
Housing and Enclosure
Type Dual compartment (terminal compartment and the electronics are completely separated).
Two entries for conduit or cable connections. The transmitter housing can be rotated in any direction
Electrical Connection ½ - 14 NPT for cable glands or conduit entries.
Optional: M20 x 1.5 conduit / cable adapter, M12 4-pin male eurofast
®
connector or A size Mini 4-pin
male minifast
®
connector. Recommended output cabling is twisted shielded pairs, 18-12 AWG
Housing Material Polyurethane-covered Aluminum, or Stainless Steel Grade CF8M (ASTM A743)
Ingress Protection NEMA 4X, IP 66, IP67
Factory Sealed Yes
Weight Transmitter Head (TH): Aluminium 4.4 lb (2 kg), SST 10.8 lb (4.9 kg).
Remote Housing Mounting Kit that includes a flexible armored extension
cable and a bracket for wall or pipe mounting.
See “Remote Housing” on page 50 for the
dimensions.
Tank Connection and Probe
Tank Connection The tank connection consists of a tank seal, a
flange, Tri-Clamp, or NPT or BSP/G threads.
Certain models of flanged Alloy and PTFE
covered probes have a tank connection
design with a protective plate of the same
material as the probe. This is to prevent the
316L / EN 1.4404 SST flange from being
exposed to the tank atmosphere.
See “Dimensional Drawings” on page 39.
Flange Dimensions Follows ASME B 16.5, JIS B2220, and EN 1092-1 standards for blind flanges.
For Proprietary Fisher
®
and Masoneilan
®
flanges, see “Special Flanges and Flushing Connection
Rings” on page 51
Vented Flanges Available with Masoneilan and Fisher vented flanges. Vented flanges must be ordered as
accessories with a 1½-in. NPT threaded process connection (code RA); see “Special Flanges and
Flushing Connection Rings” on page 51. As an alternative to a vented flange, it is possible to use a
flushing connection ring on top of the standard nozzle.
Probe Versions Coaxial, Rigid Twin and Rigid Single Lead, Flexible Twin and Flexible Single Lead. Probes can be
ordered in different materials and options for extreme temperatures and pressure
For guidelines on which probe to select depending on application, see the Technical Note Guided
Wave Radar Application Guidelines (Document No. 00840-2600-4811)
Remote Housing
Mounting Cable:
3, 6, or 9 ft (1, 2, or 3 m)
Tank seal with
protective plate
design

Other manuals for Emerson Rosemount 5300 Series

Related product manuals