EasyManua.ls Logo

Emerson Rosemount 5302 User Manual

Emerson Rosemount 5302
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Product Data Sheet
00813-0100-4530, Rev DA
December 2010
Rosemount 5300 Series
www.rosemount.com
Industry leading measurement capability and
reliability provided by direct switch technology
Increased plant availability with advanced
diagnostics and PlantWeb
®
functionality
Increased safety and proven FMEDA suitable
for SIL2 with a SFF>90%
Reduced cost and increased safety from the
robust modular design
Reduced instrument count and process
penetrations with a MultiVariable™ transmitter
Improved throughput and product quality due
to superior performance and accuracy
Reduced startup cost through powerful and
easy-to-use configuration tools and seamless
plant integration
Improved EMC performance and higher
safety with smart galvanic interface
Reduced operating costs with predictive
maintenance and easy troubleshooting
Contents
Taking Guided Wave Radar Benefits to the Next Level . . . . . . . . . . . . . . . . . . . . . . page 2
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
Functional Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
Performance Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 28
Physical Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 31
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 36
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 39
Superior Performance Guided Wave Radar
Level and Interface Transmitter
A.P.O. - ELMOS v.o.s., Pražská 90, 509 01 Nová Paka, Tel.: +420 493 504 261, Fax: +420 493 504 257, E-mail: apo@apoelmos.cz, Internet: www.apoelmos.cz
Question and Answer IconNeed help?

Do you have a question about the Emerson Rosemount 5302 and is the answer not in the manual?

Emerson Rosemount 5302 Specifications

General IconGeneral
BrandEmerson
ModelRosemount 5302
CategoryTransmitter
LanguageEnglish

Summary

Superior Performance Guided Wave Radar

Guided Wave Radar Technology Benefits

Details accuracy, reliability, and maintenance advantages of GWR.

5301/5302 Liquid Level Transmitter Ordering

5303 Solids Level Transmitter Ordering

Signal Output Options

Details HART, FOUNDATION fieldbus, and Modbus signal outputs for solids.

Housing, Connections, and Probe Types

Specifies housing, connections, probe types, and temp/pressure ratings for solids.

Functional Specification

Output and Signal Wiring

Details 4-20 mA HART output and wiring options.

Power Supply and IS Parameters

Input voltage, current, alarm, and saturation level details.

Temperature and Pressure Limits

Physical Specification

Product Certifications

FM, ATEX, CSA, and IECEx Approvals

Hazardous location certifications from major bodies.

NEPSI, INMETRO, and TIIS Approvals

Other international hazardous location certifications.

Related product manuals