Getting Started Guide
AC variable speed drive for
3 phase induction motors
from 0.25kW to 7.5kW,
0.33hp to 10hp
Model sizes A, B, C and D
Part Number: 0472-0000-09
Issue: 9
www.controltechniques.com
Commander SK
Question and Answer IconNeed help?

Do you have a question about the Emerson SKA1100025 and is the answer not in the manual?

Emerson SKA1100025 Specifications

General IconGeneral
BrandEmerson
ModelSKA1100025
CategoryInverter
LanguageEnglish

Summary

Safety Information

General Safety and Warnings

Covers warnings, electrical safety, system design, and environmental limits.

Installation and Compliance

Addresses access, fire protection, compliance, and regulations.

Motor, Brake, and Parameter Handling

Discusses motor installation, brake control, and parameter adjustment safety.

Electrical Installation Procedures

Details safety aspects of electrical installation and connection procedures.

Declaration of Conformity

Rating Data

Model Code Explanation

Details the breakdown of the Commander SK model naming convention.

1-Phase Rating Data

Lists specifications for 1-phase Commander SK drives at different voltage ratings.

1 & 3-Phase Rating Data

Lists specifications for 1 and 3-phase Commander SK drives at 200-240Vac.

3-Phase Rating Data

Lists specifications for 3-phase Commander SK drives at 380-480Vac.

Output Frequency and Voltage

Specifies output frequency range and voltage characteristics for different drive types.

Mechanical Installation

Enclosure and Fire Protection Requirements

Details enclosure specifications and fire protection measures.

Fire Enclosure Baffle Construction

Illustrates baffle construction methods for fire enclosures.

Drive Dimensions and Mounting

Provides physical dimensions and mounting options for Commander SK drives.

Minimum Mounting Clearances

Specifies required clearances between drives and around them for proper operation.

Mounting Foot Tightening Torque

Lists recommended torque values for mounting feet based on drive size.

Drive Features Overview

Display and Keypad Interface

Identifies the drive's display and keypad interface for user interaction.

Connectors and Terminals

Labels power terminals, control terminals, and communication ports on the drive.

Electrical Installation

Size A Power Terminal Connections

Shows wiring diagram for size A power terminals, including optional components.

Sizes B, C, and D Power Terminal Connections

Shows wiring diagram for sizes B, C, D power terminals, including optional components.

Fuses, Grounding, and Torque Specifications

Covers protection, grounding, and terminal tightening for safety and UL compliance.

Motor Starts per Hour and Braking Resistor Safety

Details start limitations and braking resistor safety warnings.

Ground Leakage

EMC Filter Impact on Leakage Current

Lists leakage current values with and without the internal EMC filter.

Ground Connection Requirements

Details the need for two independent ground connections to prevent safety hazards.

EMC Precautions

ELCB/RCD Types and Internal EMC Filter Use

Explains ELCB/RCD suitability and internal EMC filter recommendations.

Removing the Internal EMC Filter

Provides instructions and diagrams for removing and refitting the internal EMC filter.

Control Terminals I/O Specification

Control Circuit and PCB Connector Safety

Warns about insulation requirements for control circuits and PCB connectors.

Digital and Analog Input Notes

Provides notes on digital input logic and analog input types.

Terminal Functions and Specifications

Analog Input 1 (T2) Details

Details voltage/current input modes, scaling, impedance, and resolution for Analog Input 1.

+10V Reference Output (T3)

Specifies the maximum output current for the +10V reference output.

Analog Input 2 (T4) Details

Details voltage/digital input modes, scaling, impedance, and threshold voltage.

Status Relay (T5/T6) Operation

Describes the status relay contact ratings, isolation, and operation modes.

Analog Voltage Output (B1)

Specifies voltage output range, scaling, and current for motor speed.

+24V Output (B2)

Details the maximum output current for the +24V output.

Digital Output (B3) Specification

Describes voltage range and maximum current for the zero speed digital output.

Digital Input Functions (B4-B7)

Explains functions of digital inputs like Enable, Run, Reverse, and speed reference select.

Keypad and Display

Display Functions and Use

Lists what the keypad and display are used for, including status, faults, and parameters.

Programming and Control Keys

Describes the function of MODE, UP, DOWN, START, and STOP/RESET keys.

Selecting and Changing Parameters

Step-by-step guide on navigating and editing parameters using the keypad.

Parameter Navigation Flow

Illustrates the flow for changing parameters between Status, View, and Edit modes.

Status Modes and Indications

Describes various drive status indications and speed/load indicators.

Saving Parameters and Access Levels

Explains parameter saving and access control based on Pr 10 settings.

Security Codes Management

How to set, unlock, and re-lock security codes for parameter access.

Resetting to Default Values

Procedure for resetting drive parameters to factory default settings.

Parameters - Level 1

Minimum and Maximum Set Speed

Sets the minimum and maximum motor speeds for both directions of rotation.

Acceleration and Deceleration Rates

Defines the rates at which the motor accelerates and decelerates.

Parameters - Drive Configuration

Drive Configuration Options (Pr 05)

Details various drive configurations and their impact on terminal functions.

EUR and USA Configuration Examples

Shows terminal wiring diagrams for different configurations in EUR and USA setups.

Pr 05 = AV.Pr Configuration Details

Wiring diagram and reference selection for AV.Pr configuration.

Pr 05 = Al.Pr Configuration Details

Wiring diagram and reference selection for Al.Pr configuration.

Pr 05 = Pr Configuration Details

Wiring diagram and reference selection for Pr configuration.

Pr 05 = PAd Configuration Details

Wiring diagram for PAd configuration and setup for Forward/Reverse terminal.

Pr 05 = E.Pot Configuration Details

Wiring diagram for E.Pot configuration and available motorized pot parameters.

Pr 05 = tor Configuration Details

Wiring diagram for torque mode configuration and safety warning.

Pr 05 = Pid Configuration Details

Wiring diagram and parameters for PID control configuration.

PID Logic Diagram

Visual representation of the PID control loop logic and parameters.

Parameters - HVAC Configuration

HVAC Terminal Configuration (Pr 05)

Shows terminal wiring for HVAC configuration.

Motor Parameter Settings (Pr 06-08)

Setting motor current, speed, and voltage for optimal control.

Parameters - Motor and Brake Control

Motor Power Factor and Access Levels

Setting motor power factor and configuring parameter access levels.

Start/Stop Logic and Brake Control

Configuring start/stop logic and enabling mechanical brake control.

Jog Reference and Analog Input 1 Mode

Configuring jog speed and Analog Input 1 for current/voltage modes.

Enable Negative Preset Speeds

Controls direction of rotation based on preset speeds or keypad reference.

Parameters - Speed and Security

Preset Speeds and Display Units

Defines preset speeds and configures display units for load and speed.

User Security and Parameter Copying

Sets up user security codes and enables parameter copying via SmartStick.

Parameters - Defaults and Ramps

Loading Default Parameters (Pr 29)

Loads factory default parameter settings for EUR or USA.

Ramp Mode Selection (Pr 30)

Selects ramp modes for controlled acceleration and deceleration.

Parameters - Motor Control Functions

Stop Modes and Dynamic V/f

Configures motor stop modes and dynamic voltage-to-frequency ratio.

Spinning Motor Catch and Terminal Modes

Enables spinning motor catch and configures terminal modes.

Parameters - Output Control and Autotune

Digital and Analog Output Configuration

Configures the functions of digital (B3) and analog (B1) outputs.

Switching Frequency and Autotune

Sets switching frequency and enables autotune for motor optimization.

Parameters - Motor Data and Voltage Mode

Motor Data Settings (Pr 39-40)

Sets motor rated frequency and number of poles for control.

Voltage Mode Select (Pr 41)

Selects voltage control modes like Fixed Boost or Square Law for motor control.

Parameters - Communications and Brake Control

Serial Communication Settings

Configures baud rate and address for serial communication.

Brake Control Parameters (Pr 46-51)

Configures current thresholds, frequencies, and delays for brake control.

Brake Function Diagrams

Brake Control Logic Diagram

Visualizes how brake release and hold are managed based on various inputs.

Brake Sequence Diagram

Shows the timing and sequence of brake release and ramp hold operations.

Parameters - Solutions Module and PLC

Solutions Module and PLC Parameters

Covers parameters for Solutions Modules and PLC ladder program control.

Advanced Parameter Access Setup

Configures access to advanced parameters for customization.

Parameter Descriptions - Level 3

Diagnostic Parameters (Pr 81-95)

Provides read-only parameters for diagnosing drive faults and conditions.

Quick Start Commissioning

Terminal Control Connections

Shows minimum required control terminal connections for basic operation.

Power Up and Motor Data Entry

Steps for powering up the drive and entering motor nameplate details.

Autotune Procedure

Guides through the non-rotating autotune process for motor optimization.

Running and Stopping the Motor

Instructions for running the motor and controlling its speed and stopping.

Keypad Control Setup

Details how to implement keypad control and set up Forward/Reverse switching.

Diagnostics

Trip Codes and Conditions

Details various trip codes, their conditions, and potential causes.

DC Bus Voltages and Alarm Indications

Provides DC bus voltage trip levels and alarm warning solutions.

Diagnostics Logic Diagram

Visualizes the logic flow for drive diagnostics and parameter monitoring.

Options

SmartStick and LogicStick Options

Describes options for parameter storage and PLC programming.

I/O Modules and Fieldbus Options

Details additional input/output modules and fieldbus communication options.

Keypad, EMC Filters, and Brackets

Lists keypad options, EMC filters, and cable management brackets.

Communication Cables and Software

Lists communication cables, PC software for commissioning, and PLC programming.

Documentation and Guides

Lists available documentation, technical guides, and user manuals.

UL Listing Information

UL Conformity Requirements

Specifies conditions for UL listing, including wire type, temperature, and enclosure.

AC Supply and Motor Overload Protection

Covers AC supply specifications and motor overload protection levels.