EasyManua.ls Logo

Emerson TESCOM - Intended Use; Installation

Emerson TESCOM
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
TESCOM™ Safety, Installation, Operations & Service Manual
Content
December 2020
Installation Manual
TR000238ENUS-01_12-20
Someuidswhenburningdonotexhibitavisibleame.Useextremecaution
wheninspectingand/orservicingsystemsusingammableuidstoavoiddeathor
serious injury to personnel. Provide a device to warn personnel of these dangerous
conditions.
Many gases can cause suffocation. Make certain the area is well ventilated. Provide a
device to warn personnel of lack of Oxygen.
Never use oil or grease on these regulators, valves, or accessories unless
recommendedasspeciedinOperationsandServiceprocedures.Oilandgreaseare
easilyignitedandmaycombineviolentlywithsomeuidsunderpressure.
Haveemergencyequipmentintheareaiftoxicorammableuidsareused.
Upstream filters are recommended for use with all fluids.
Donotbleedsystembylooseningttings.
Prevent icing of the equipment by removing excess moisture from the gas.
Always use proper thread lubricants and sealants on tapered pipe threads.
Intended Use
Regulators: Pressure regulators are intended to be used to regulate the pressure at which
uidsareadministeredinanapplication.Additionalregulationsthatsupplementorlimit
theintendedusemayapplydependingontheregulatorandmediaorindustry-specic
standards. Regulators are not intended for use as a pressure or safety relief valve.
Valves:TESCOMValvesareintendedtobeusedtocontrolgasowinpipedsystems.They
are not intended for use as a pressure reducer.
Installation
CAUTION
Do not open packaging until ready for installation or in a clean environment. Product is
cleanedinaccordancewithCGA4.1andASTMG93,VericationType1,Test1andTest2.
WithperiodicvericationofcleaningprocesstoMIL-STD-1330D.
WARNING
Makesurethatthecomponentsandmaterialsusedintheuidhandlingsystemare
compatiblewiththeuidandhavetheproperpressurerating.Failuretodosocanresultin
death, serious injury, and/or property damage.
Inspect the regulator, valve, and accessories for physical damage and contamination. Do
not connect the regulator, valve, or accessory if you detect oil, grease, or damaged parts. If
the regulator, valve, or accessory is damaged, contact your local TESCOM representative to
have the regulator cleaned or repaired.
2.1.1
2.1.2

Related product manuals