16 Unidrive M200-201 Quick Start Guide
Issue Number: 6
Figure 4-4 Pr 00.005 = AI. (60 Hz)
Figure 4-5 Pr 00.005 = AV.Pr (50 Hz)
*Refer to Drive User Guide.
1
2
4
0V
Current speed
reference input
Current speed reference
input (AI 1)
Voltage speed reference
input (AI 2)
5
+ 10 V output
7
9
10
Digital output
(zero frequency)
Not stop
11
12
13
14
Jog forward
Run
Analog output 1
(motor frequency)
Analog input 1/
input 2 select
+ 24 V output
10k
1
2
4
0V
Voltage speed reference
Reference select
input (AI 1)
5
+ 10 V output
7
9
10
Digital output
(zero frequency)
Drive enable
11
12
13
14
Run reverse
Run forward
Analog output 1
(motor frequency)
Reference select
+ 24 V output
10k
Terminal 5 Terminal 14 Reference selected
0 0 Analog reference 1*
0 1 P r e s e t s p e e d 2 *
1 0 Preset speed 3*
1 1 Preset speed 4*
Unidrive M200 201 Quick Start Guide English Iss6.book Page 16 Thursday, September 10, 2015 1:48 PM