Unidrive M200-201 Quick Start Guide 37
Issue Number: 6
If the preset reference has been selected (see Pr 00.005), the speed at which the motor runs is
determined by these parameters.
See Drive Configuration (00.005).
If any number other than 0 is programmed into this parameter, user security can be applied so that
no parameters except Pr 00.010 can be adjusted with the keypad. When this parameter is read via a
keypad it appears as zero. Refer to the Drive User Guide for further information.
Defines which value of keypad control mode reference is displayed at power-up.
Defines the mode used by the ramp system.
0: Fast ramp
1: Standard ramp
2: Standard ramp with motor voltage boost
00.018 {01.021} Preset Reference 1
RW Num US
OL
Ú
±VM_SPEED_FREQ_REF Hz
Ö
0.00 Hz
RFC-A
00.025 {11.030} User Security Code
RW Num ND NC PT US
OL
Ú
0-9999
Ö
0
RFC-A
00.027 {01.051} Power-up Keypad Control Mode Reference
RW Txt ND NC PT US
OL
Ú
Reset (0), Last (1), Preset (2)
Ö
Reset (0)
RFC-A
Value Text Description
0 Reset Keypad reference is zero
1 Last Keypad reference is the last used value
2 Preset Keypad reference is copied from Preset Reference 1 (00.018)
00.028 {02.004} Ramp Mode Select
RW Txt US
OL
Ú
Fast (0), Std (1), Std.bst (2),
Fst.bst (3)
Ö
Std (1)
RFC-A
Unidrive M200 201 Quick Start Guide English Iss6.book Page 37 Thursday, September 10, 2015 1:48 PM