Defines the event number to trigger in the given destination (slot) when a late
synchronized frame is received on the Rx2 link.
This parameter defines the action to be taken when a late synchronized frame is
received on the Rx3 link.
S.11.052 Rx2 Late Synchronisation Frame Event
Minimum 0 Maximum 4
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, TE, BU
Value Text Description
0 No Event No event
1 Event Trigger module event
2 Event 1 Trigger module event 1
3 Event 2 Trigger module event 2
4 Event 3 Trigger module event 3
This feature is not yet implemented.
S.11.060 Rx3 Late Synchronisation Frame Action
Minimum 1 Maximum 3
Default 1 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, TE, BU
Value Text Description
1 Trip Trip drive with Slx.Er and sub-trip code
2 Do not use The data is ignored